OBSERVE THE ROOM BEFORE CHANGING IT Section diagram: positions are illustrative, not construction sizes.
Exterior screen intercepts sun
Keep required vents open
°c
Sensor in occupied zone, away from sun and heaters.
LOG: time · indoor °C · outdoor °C · humidity if measured Add symptoms, action and recheck. Preserve the sensor position.
HEAT + confusion, collapse or seizures: urgent medical help. Move to a cool place. Start cooling with wet cloths. Stay with the person; do not wait for a thermometer.
COLD + confusion or slurred speech: urgent medical help. Move gently to shelter; remove wet clothes; warm the torso. No drinks if unconscious or unable to swallow safely.
CDC : Centers for Disease Control and Prevention The United States public health agency credited with the cited information.
Make a shade and a dry draught roll
1. Assemble the removable screen Centre the mesh over the measured opening for 200 mm overlap per side. Fit the eight grampas following their instructions; attach the eight cut ties. Use assessed existing supports and an air gap from glass. Work from ground level in calm weather. Remove before strong wind; keep cords away from children.
2. Sew the burlete Fold the cotton lengthwise. Stitch the long edge and one end 10 mm in, turn out, loosely fill with clean dry cloth offcuts and close the remaining end. Keep the roll dry, removable and away from heaters. Never obstruct a door, flue, gas vent or required air supply.
3. Operate for the season Admit useful winter sun; close curtains after dark. Use dry layers and bedding. Gas appliances need a gasista matriculado. Never heat indoors with a grill, camping stove or generator. Open for cooling only when outside air is cooler and safe. Use the planned refuge if conditions remain unsafe.
Material basket · argentina · 5 nov 2026
2 m² mesh / 1 linear metre 5,000
20 clips purchased / 8 used 4,000
5 m cord × ARS 175/m 875
ARS 9,875 ≈ USD 6.29 at BNA ARS 1,570/USD. Tools, supports, labour, delivery and instruments are additional.
REMOVABLE SHADE: CUTTING AND SET-OUT Example opening: 1.60 × 0.60 m. Dimensions in mm; diagram not to scale.
2,000
Window behind mesh 1,600 × 600
1,000
8 clips: 4 corners + 4 edge midpoints. Exact fitting follows the clip maker. 8 ties × 0.60 m = 4.80 m. Buy 5 m; retain 0.20 m before cutting losses. No anchor or wind rating is supplied. Keep escape routes and vents clear.
Sewn burlete: cloth and seam allowances
1,020 × 180 mm cloth
10 mm seams; fold on centre line
Finished length ≈ 1,000 mm; ideal circumference ≈ 160 mm. Cylinder capacity: 1,000 × 160² / (4π) ≈ 2,037,000 mm³ ≈ 2.04 L. Cloth, clean dry offcuts, needle and thread: reused or separately priced. Keep removable, dry and clear of required ventilation and heaters.
Sanitation
Sanitation: break the route from waste to water
Read the historic evidence John Snow’s map in the 1855 St James parish report marks deaths and public pumps around London’s Broad Street outbreak of 1854. The concentration is a reason to investigate shared water exposure; it is not a licence to infer causation from a map alone.
Units and terms in this account
°C degree Celsius, a temperature unit · SMN Servicio Meteorológico Nacional
°C degree Celsius, a temperature unit · mm millimetre, 0.001 metre · m² square metre, an area unit · ARS Argentine peso · m metre, a length unit · × multiplied by · USD United States dollar · BNA Banco de la Nación Argentina · ≈ approximately equal to
× multiplied by · m metre, a length unit · = equals · mm millimetre, 0.001 metre · L litre, a volume unit · ≈ approximately equal to
L litre, a volume unit · × multiplied by