A working idea from Ghana Biological scientist Veronica Bekoe worked in Ghana’s health service from 1972 to 2008. In 2005, the service recognised her invention of the Veronica Bucket. A tap supplies running water without a pipe connection.
Read the actual photograph This 2021 photograph shows a later installation: covered reservoir, tap, sink and stand. It does not prove water quality or reveal where the drain ends. The Argentine assembly opposite applies this delivery principle.
Wash at the change of task After the toilet or handling waste, and before food preparation or eating, wet with safe running water and soap. Rub palms, backs, between fingers, thumbs, nails and wrists for at least 20 seconds. Rinse fully; dry with clean paper. Use the paper to close a hand-operated tap, then discard it.
Adapt to the Argentine site Follow the proveedor de agua and municipio or comuna’s advisories. Keep the station shaded and supplies protected from dust. In frost-prone areas, use a protected location and check flow. Set the height and reach for actual users; supervise children. No loose stacked supports or shared dipping bowl. Earlier source record: 1205
RUNNING WATER WITHOUT A PIPE CONNECTION Assembly section, not to scale. Use assessed existing supports.
Safe water
10 L nominal
280 × 160 × 340 mm length × width × height
Air vent: use maker’s instruction.
Keep the cap closed. No dipping cups or hands inside.
Low outlet: inspect seal, tap and flow.
RUNOFF ONLY 20 L bucket Mark 5 L by measurement. Empty then, or earlier for safe lifting. Catch runoff without excessive splash.
Dry side: soap on a draining dish; paper kept covered.
SEPARATE THE ROUTES Clean refill tools stay with the supply. Runoff goes to the agreed local route.
Assemble, measure and keep the station working
1. Prepare and assemble Use a purpose-made potable-water jug, never a former fuel or chemical container. Clean it, the cap and tap as their maker directs; use only a compatible food-contact treatment at its labelled dilution and contact time. For the listed Soch unit, remove the orange cap, turn the transported tap and O-ring outwards and refit the white nut. Do not drill another outlet.
2. Test before opening Fill with locally approved safe water and close the cap. Set the jug securely on sound, level existing support; ten litres add about 10 kg before vessel mass. Operate the air vent as instructed. Check for leaks, smooth flow, safe reach and splash into the catch vessel. Keep soap and dry paper outside the splash path. Adjust the setup before use.
3. Operate, empty and clean Check water, soap, paper, leaks and catch level at opening and each refill. Close the tap during rubbing. Empty the catch at the marked 5 L level, or earlier for safe handling, and before a refill. Use only a disposal route agreed with the local sanitation operator; never a storm drain, food plot or drinking-water source. Clean spills and high-touch surfaces; keep the walking surface dry.
4. Close the service loop Assign one operator and log date, source water, refills, washes, cleaning and wastewater removal. Never return runoff to the reservoir. Keep clean refill tools separate from the wastewater bucket. Close the station if safe supply, drainage, soap or cleaning fails; provide a working alternative. Replace damaged seals and containers before returning to service.
MEASURE THE CYCLE, THEN PLAN THE STOCK Illustrative readings only. Repeat with proper washing and actual users.
5 washes 8.0 − 5.0 = 3.0 L used
3.0 ÷ 5 = 0.60 L / wash
Record spills separately.
Recheck if flow or users change.
Before: 8.0 l after: 5.0 l
EXAMPLE DAY: 4 people × 8 assumed washes = 32 washes (32 × 0.60 L + 2 L cleaning allowance) × 1.30 = 27.56 L
Round up to 28 L. The 30% reserve is a planning choice, not a standard.
At 1.00 L / wash: 44.2 L. Never shorten washing to meet a ration.
COUNTED ARGENTINE STARTER BASKET 4 NOV 2026 · Catalogue list prices in ARS; no discounts assumed.
1 bidón con canilla, Soch 10 L 32,800 1 balde con tapa, 20 L 13,980 1 jabón de tocador, 90 g 710 1 pack toallas intercaladas, 2,500 sheets 29,840
PURCHASED ITEMS: ARS 77,330 ≈ USD 49.25 USD basis: BNA selling ARS 1,570 / USD, 4 NOV 2026. Also count: 1 support, 1 soap dish, 1 paper holder, 1 rubbish bin, 1 measuring jug, 2 labels + marker. Reuse or obtain separate prices. Safe water, reserve storage, cleaners, labour and delivery are extra.
BNA : Banco de la Nación Argentina The Argentine bank whose exchange-rate quotation provides a reference for the calculation. L : Litre One cubic decimetre of volume, or one thousand millilitres. g : Gram A unit of mass equal to one thousandth of a kilogram.
Units and terms in this account
L litre, a volume unit · mm millimetre, 0.001 metre · × multiplied by · kg kilogram, a mass unit
L litre, a volume unit · = equals · ÷ divided by · × multiplied by · % percent, parts per hundred · ARS Argentine peso · g gram, 0.001 kilogram · USD United States dollar · BNA Banco de la Nación Argentina · ≈ approximately equal to