The drawing defines an original classroom layout: a 600 × 400 mm lid with six positions on a 200 mm grid. From the upper-left corner, the centres are at 100, 300 and 500 mm across, with rows 100 and 300 mm down. The nominal 80 mm cup openings must be checked against the actual cup rims before any cutting. The rim must carry the cup; a loose fit is a failed part.
Read the illustration’s labels
Six lettuce plants: count the seats and fittings
Classroom demonstrator: measure the actual reservoir and cup rims before cutting.
LID PLAN
1
2
3
4
5
6
600 mm
400
mm
200 mm
Centres: x = 100, 300, 500 mm; y = 100, 300 mm.
Six nominal 80 mm seats; size each to its cup rim.
COUNTED MATERIALS
1 opaque food-contact reservoir
+ fitted lid
6 net cups + 6 starter plugs + 6 seedlings
1 air pump + 1 air stone + 1 check valve
1 air tube, measured for the installed route
1 protected lamp + 1 timer
1 measuring jug + labelled nutrient container
1 pH/EC meter + 1 thermometer
15 L measured starting charge
for this example; adjust to the actual root level
SECTION THROUGH TWO CUPS
Air pump
Check valve: flow to stone
Pump stays above water.
Roots reach the solution.
Keep the crown above it.
Measure fill; do not infer depth from 15 L.
Air stone
Section is schematic. The 600 × 400 mm plan is a teaching layout, not a reservoir manufacturing drawing.
Use suitable electrical protection and keep connections dry. This six-plant trial is not a full food supply.
Choose an opaque, cleanable, food-contact reservoir and matching supported lid. The trial uses a measured initial charge of 15 litres. This quantity is not calculated from external box dimensions: wall thickness, corners and internal fittings change the volume. Select the vessel and cup depth so the prepared solution can reach the lower plug or emerging roots while the crown remains above it. Mark the actual fill level after measuring the charge.
Nebraska Extension’s Lunchbox Hydroponics demonstrates how a small classroom system can expose plant growth to observation. Its published noncirculating method differs from this aerated design. The operating water level and air space of one method must not be copied into the other without understanding the root environment.
The tray belongs indoors on a stable, waterproof working surface. Provide access to lift each cup and read the water level. Its plan dimensions define the teaching object, not the dimensions or insulation of a polar greenhouse.
Use this bill of materials to specify a small demonstration, then replace the allowances with local quotations. Dimensions, food-contact suitability, electrical compatibility and replacement availability matter more than a product photograph. The lamp and pump ratings below are accounting assumptions; they do not certify adequate crop lighting or aeration.
| Item | Quantity or specification |
|---|---|
| Reservoir and supported lid | 1 set, planned 600 × 400 mm lid |
| Net cups | 6, fitted to actual rim size |
| Starter plugs | 12; six positions plus sowing reserve |
| Named lettuce seed | 1 packet; record lot and sowing count |
| Hydroponic nutrient product | 1 trial allowance; actual dose from label |
| Air pump | 1, 3 W example rating |
| Airline, check valve and diffuser | 1 matched set |
| Suitable LED fixture | 1, 30 W example rating |
| Timer | 1, compatible with fixture |
| Graduated measuring jug | 1 |
| pH/EC meters and standards | 1 shared set |
| Thermometer | 1 shared instrument for room/solution readings |
| Scale | 1 shared instrument |
| Labels and cleaning materials | 1 trial allowance |
Shared workshop tools are a ruler, marker, suitable hole-cutting tool, eye protection and a way to finish sharp edges. Have a competent adult prepare the lid. Keep cutting debris away from the growing system. Borrow measuring equipment where practical, but record whose instrument was used and how its reading was checked.
Position electrical equipment away from splashes and use intact equipment intended for the location, with appropriate residual-current protection. Place the air pump above the liquid level or use the manufacturer’s specified backflow protection. A drawing of a check valve is not proof that an installed valve faces the correct direction. Confirm operation before plants are introduced.
Keep six cups assigned to the growing positions and use the extra plugs only as a recorded sowing reserve. Replacing a failed seedling can be useful, but it changes the age of that position. Label the replacement and retain the original failure in the record.
Units and terms in this account
mm millimetre, 0.001 metre · × multiplied by
mm millimetre, 0.001 metre · L litre, a volume unit · = equals · × multiplied by
LED Light-emitting diode · mm millimetre, 0.001 metre · W watt, power · × multiplied by
ARS Argentine peso · USD United States dollar · EUR Euro · LED Light-emitting diode · mm millimetre, 0.001 metre · W watt, power · × multiplied by