The drawing defines an original classroom layout: a 600 × 400 mm lid with six positions on a 200 mm grid. From the upper-left corner, the centres are at 100, 300 and 500 mm across, with rows 100 and 300 mm down. The nominal 80 mm cup openings must be checked against the actual cup rims before any cutting. The rim must carry the cup; a loose fit is a failed part.

Read the illustration’s labels

Six lettuce plants: count the seats and fittings

Classroom demonstrator: measure the actual reservoir and cup rims before cutting.

LID PLAN

1

2

3

4

5

6

600 mm

400

mm

200 mm

Centres: x = 100, 300, 500 mm; y = 100, 300 mm.

Six nominal 80 mm seats; size each to its cup rim.

COUNTED MATERIALS

1 opaque food-contact reservoir

+ fitted lid

6 net cups + 6 starter plugs + 6 seedlings

1 air pump + 1 air stone + 1 check valve

1 air tube, measured for the installed route

1 protected lamp + 1 timer

1 measuring jug + labelled nutrient container

1 pH/EC meter + 1 thermometer

15 L measured starting charge

for this example; adjust to the actual root level

SECTION THROUGH TWO CUPS

Air pump

Check valve: flow to stone

Pump stays above water.

Roots reach the solution.

Keep the crown above it.

Measure fill; do not infer depth from 15 L.

Air stone

Section is schematic. The 600 × 400 mm plan is a teaching layout, not a reservoir manufacturing drawing.

Use suitable electrical protection and keep connections dry. This six-plant trial is not a full food supply.

Choose an opaque, cleanable, food-contact reservoir and matching supported lid. The trial uses a measured initial charge of 15 litres. This quantity is not calculated from external box dimensions: wall thickness, corners and internal fittings change the volume. Select the vessel and cup depth so the prepared solution can reach the lower plug or emerging roots while the crown remains above it. Mark the actual fill level after measuring the charge.

Nebraska Extension’s Lunchbox Hydroponics demonstrates how a small classroom system can expose plant growth to observation. Its published noncirculating method differs from this aerated design. The operating water level and air space of one method must not be copied into the other without understanding the root environment.

The tray belongs indoors on a stable, waterproof working surface. Provide access to lift each cup and read the water level. Its plan dimensions define the teaching object, not the dimensions or insulation of a polar greenhouse.

Use this bill of materials to specify a small demonstration, then replace the allowances with local quotations. Dimensions, food-contact suitability, electrical compatibility and replacement availability matter more than a product photograph. The lamp and pump ratings below are accounting assumptions; they do not certify adequate crop lighting or aeration.

ItemQuantity or specification
Reservoir and supported lid1 set, planned 600 × 400 mm lid
Net cups6, fitted to actual rim size
Starter plugs12; six positions plus sowing reserve
Named lettuce seed1 packet; record lot and sowing count
Hydroponic nutrient product1 trial allowance; actual dose from label
Air pump1, 3 W example rating
Airline, check valve and diffuser1 matched set
Suitable LED fixture1, 30 W example rating
Timer1, compatible with fixture
Graduated measuring jug1
pH/EC meters and standards1 shared set
Thermometer1 shared instrument for room/solution readings
Scale1 shared instrument
Labels and cleaning materials1 trial allowance

Shared workshop tools are a ruler, marker, suitable hole-cutting tool, eye protection and a way to finish sharp edges. Have a competent adult prepare the lid. Keep cutting debris away from the growing system. Borrow measuring equipment where practical, but record whose instrument was used and how its reading was checked.

Position electrical equipment away from splashes and use intact equipment intended for the location, with appropriate residual-current protection. Place the air pump above the liquid level or use the manufacturer’s specified backflow protection. A drawing of a check valve is not proof that an installed valve faces the correct direction. Confirm operation before plants are introduced.

Keep six cups assigned to the growing positions and use the extra plugs only as a recorded sowing reserve. Replacing a failed seedling can be useful, but it changes the age of that position. Label the replacement and retain the original failure in the record.

Units and terms in this account

mm millimetre, 0.001 metre · × multiplied by

mm millimetre, 0.001 metre · L litre, a volume unit · = equals · × multiplied by

LED Light-emitting diode · mm millimetre, 0.001 metre · W watt, power · × multiplied by

ARS Argentine peso · USD United States dollar · EUR Euro · LED Light-emitting diode · mm millimetre, 0.001 metre · W watt, power · × multiplied by