These are editorial planning allowances authored on 16 November 2026, not retail quotations. They are a worked budget for the classroom object, not an estimate for shipping, constructing or operating an Antarctic facility. The entire initial equipment purchase is shown; reusable instruments should not silently become a recurring cost for every harvest.
| Item and quantity | ARS | USD | EUR |
|---|---|---|---|
| Reservoir and supported lid · 1 set, planned 600 × 400 mm lid | 31,400 | 20.00 | 17.74 |
| Net cups · 6, fitted to actual rim size | 14,130 | 9.00 | 7.98 |
| Starter plugs · 12; six positions plus sowing reserve | 9,420 | 6.00 | 5.32 |
| Named lettuce seed · 1 packet; record lot and sowing count | 6,280 | 4.00 | 3.55 |
| Hydroponic nutrient product · 1 trial allowance; actual dose from label | 7,850 | 5.00 | 4.44 |
| Air pump · 1, 3 W example rating | 23,550 | 15.00 | 13.31 |
| Airline, check valve and diffuser · 1 matched set | 12,560 | 8.00 | 7.10 |
| Suitable LED fixture · 1, 30 W example rating | 54,950 | 35.00 | 31.05 |
| Timer · 1, compatible with fixture | 12,560 | 8.00 | 7.10 |
| Graduated measuring jug · 1 | 7,850 | 5.00 | 4.44 |
| pH/EC meters and standards · 1 shared set | 70,650 | 45.00 | 39.92 |
| Thermometer · 1 shared instrument for room/solution readings | 12,560 | 8.00 | 7.10 |
| Scale · 1 shared instrument | 23,550 | 15.00 | 13.31 |
| Labels and cleaning materials · 1 trial allowance | 12,560 | 8.00 | 7.10 |
| Initial listed total | 299,870 | 191.00 | 169.42 |
Comparison basis: Banco Nación’s bill-sale table observed on 16 November 2026 at 10:01 gives ARS 1,570 per USD and ARS 1,770 per EUR. Thus an allowance of USD 20 becomes ARS 31,400, and that peso amount becomes EUR 17.74. These are comparison equivalents using the two stated sale rates; they are not a promise that a purchase or conversion will settle at that cross-rate.
Add electricity, water, labour, delivery, applicable taxes and any replacement parts separately. Mark any included tax explicitly. To compare suppliers, keep the specification constant: a cheap uncalibrated meter and a tested instrument with calibration solution are not the same purchase. Retain the supplier, date and unit price beside each replaced allowance.
1. Check the parts dry. Seat all six cups, support the lid and confirm that the reservoir remains stable when filled. Number the positions one to six. Put a matching number on the crop sheet, where replacements and losses can be traced.
2. Prepare the water account. Measure the initial charge with the jug instead of guessing from a wall mark. Record the source water, date and volume. Keep the nutrient product and its instructions available. Measure each component according to its label; do not mix concentrated products together unless their instructions require it.
3. Test aeration and leaks. Connect the matched pump, tubing and diffuser under the equipment instructions. Observe bubbling and inspect joints, the lid and the surrounding surface. Disconnect equipment safely before repositioning anything wet. A successful empty test is recorded separately from later operation with roots.
4. Set and verify the timer. Record the programmed hours and observe an actual switch-on and switch-off. Note fixture height and the lit footprint. In this trial, 14 hours is a chosen starting schedule for the accounting example, not a claim that any 30 W lamp provides adequate light.
5. Start the seedlings as a named batch. Record seeds sown, emergence and losses. Transfer established plugs with accessible young roots into the cups without crushing roots or burying crowns. Record the transplant date for each position. Keep reserve seedlings labelled instead of mixing ages without a record.
6. Establish a baseline. Before the first unattended period, record water level, pH, EC, room temperature, plant count and a dated photograph. Note the instrument identifiers. Name the person who will inspect the tray next and show them the normal pump sound and water mark.
7. Review daily. A new leak, stopped pump, unusual smell, damaged leaf or root change is an observation to investigate, not a reason to add an unidentified chemical. Record what changed and the action taken. If equipment or water quality is unsafe, stop the trial and resolve the cause before using its produce.
Units and terms in this account
ARS Argentine peso · USD United States dollar · EUR Euro · LED Light-emitting diode · mm millimetre, 0.001 metre · W watt, power · × multiplied by
pH A logarithmic measure of hydrogen-ion activity · EC Electrical conductivity, a water-quality measurement
