1 COUNT AND IDENTIFY THE PARTS Use 3 × 20 L food-contact water containers with matched lids, taps and seals; 3 labels; 1 permanent marker; 1 measuring jug; 1 logbook and a washable spill tray. Select water vessels, never reused fuel or pesticide containers. A full 20 L unit holds about 20 kg of water plus its own mass. Choose smaller units if users cannot handle it [D658, D659].

2 PREPARE AND ASSEMBLE Wash with soap, rinse, then sanitise by a suitable product/container procedure and drain as directed. Container sanitising is a different task from treating drinking water. On the cited Soch model, reverse the transport-position tap and O-ring and refit the nut exactly as instructed [D659]. Do not drill an unknown vessel or substitute an unverified seal. Check for leakage before storing water.

3 PLACE, FILL AND PROVE USABILITY Keep reserve vessels low, secure and away from heat, sunlight and chemicals. Place only the dispensing unit on a stable surface rated for its filled load, with room for the cup below its outlet. Fill with known safe water; mark A, B and C, source, volume and date. Test opening, venting, pouring and closing with the actual users. Keep hands and cups out of stored water [D658].

4 RECORD EACH CHANGE Write opening stock + additions − withdrawals = closing stock. Record isolated or unusable litres separately; investigate unexplained differences. Use the oldest suitable supply first. Replace home-filled emergency water every six months, sooner if contamination or damage is suspected [D658].

ARGENTINE CONTAINER BASKET Soch lists a 20 L water bidón at ARS 36,900, dimensions 330 × 250 × 390 mm. Three cost ARS 110,700, comparison USD 70.51 [D659, D657]. The 60 L is capacity; only filled, safe, accessible litres count. Water, cleaning materials, labels, support, tests, labour and freight are additional.

FROM HOUSEHOLD TO COMMUNITY Duplicate this station with labelled ownership and separate records before pooling supplies. Count people and measured daily demand, then verify refill transport and source testing. In an AySA area, check internal tank responsibility with the consorcio; cleaning or entering roof tanks is a separate competent-service task [D668].

Read the illustration’s labels

ASSEMBLE A CLEAN DISPENSING STATION

Example vessel: 330 × 250 × 390 mm; filled water mass about 20 kg

Vent

A · 20 L

Date / source

1 Correct lid, seal and tap

2 Label volume, source and date

3 Cup stays clear of outlet

4 Stable, rated support; spill tray

Reserve vessels stay low and secure.

In the drawing: ASSEMBLE A CLEAN DISPENSING STATION Example vessel: 330 × 250 × 390 mm; filled water mass about 20 kg; 1 Correct lid, seal and tap; Vent; A · 20 L; 2 Label volume, source and date; Date / source; 3 Cup stays clear of outlet; 4 Stable, rated support; spill tray; Reserve vessels stay low and secure.

AySA : Agua y Saneamientos Argentinos The water and sanitation provider named in the Buenos Aires context. L : Litre One cubic decimetre of volume, or one thousand millilitres. D + number : Book evidence record The number identifies a source entry in the book’s evidence section. The linked record gives the title, credit or publication details.

Collect, treat and verify the water

Read the illustration’s labels

RAINWATER: COLLECTION IS NOT DISINFECTION

Leaf screen

First runoff diverted

Closed tank

+ overflow

Treatment

then clean

storage

Suitable roof + gutter

In the drawing: RAINWATER: COLLECTION IS NOT DISINFECTION; Treatment then clean storage Suitable roof + gutter; Closed tank + overflow; Leaf screen; First runoff diverted

Related reserve lesson: 899

1 COLLECT THE RAIN; 2 SIZE THE STORAGE For rainwater, identify a suitable roof, gutter, leaf screen, initial-runoff diverter, covered cistern, screened overflow and draw-off point [D665]. Inspect roof contamination and material suitability before collection. Keep untreated rainwater clearly separate from drinking-water pipes. Foundation, supports, overflow routing and local approvals need a site-specific design. For an assumed 40 m² catchment and 20 mm rain, gross volume is 800 L. An assumed overall collection factor of 0.80 gives 640 L. Do not subtract the same losses twice. If only 300 L of tank space remains, no more than 300 L is retained and 340 L overflows in this example. Monthly rainfall, dry spells and demand determine useful storage; one storm does not establish annual supply.

ARGENTINA: CHECK THE ACTUAL SOURCE CABA/conurbano: identify network, tank and pump responsibility. Interior Buenos Aires: test private wells. Vera, Santa Fe: 85 aljibes planned in 2018 for salt/arsenic constraints [D666]. Near Jacobacci, Río Negro: CNEA sampled arsenic/fluoride across seasons [D667]. NOA, Cuyo and other southern sites: verify yield, drought, frost and delivery locally. No province-wide ranking.

3 REJECT THE WRONG SOURCE FIRST Fuel, toxic chemicals and radioactive contamination are not corrected by boiling or household disinfection [D663]. Arsenic and fluoride need tested source-specific solutions, not an improvised charcoal filter [D664, D667]. Obtain alternative safe water while a laboratory and local health authority assess the source.

4 TREAT MICROBIAL RISK CORRECTLY If water is cloudy, settle and remove particles first; cloth alone does not disinfect. For microbial treatment, bring water to a rolling boil for 3 minutes, then cool covered [D662, D663]. Use a stable vessel and a safe heat source; this does not remove dissolved chemicals.

5 IF USING REGISTERED LAVANDINA Use only a product whose label says “apta para desinfectar agua”; follow its concentration, dose and contact time. The Health Ministry example for 55 g Cl/L is 2 drops/L and 30 minutes: 20 L × 2 = 40 drops, only when the actual label matches [D662]. Mix and wait before use. Do not substitute perfumed bleach, gel or vegetable-washing doses; never mix chemicals. Chlorine is less effective against some parasites [D663].

6 VERIFY AND KEEP CLEAN Ask a local laboratory for relevant microbial and chemical tests against CAA Article 982 [D664]. Treatment equipment needs a validated process and maintenance plan. Use clean covered storage after treatment. Record source, method, batch, time and responsible person; follow any stricter local water advisory.

CABA : Ciudad Autónoma de Buenos Aires The autonomous city of Buenos Aires, a distinct jurisdiction within the wider metropolitan area. CNEA : Comisión Nacional de Energía Atómica Argentina’s national atomic energy commission, credited with the environmental sampling research.

NOA : Noroeste Argentino Northwestern Argentina. The abbreviation locates the region discussed.

Units and terms in this account

L litre, a volume unit · = equals · ÷ divided by · kg kilogram, a mass unit · × multiplied by · ARS Argentine peso · USD United States dollar · mm millimetre, 0.001 metre

mm millimetre, 0.001 metre · kg kilogram, a mass unit · L litre, a volume unit · × multiplied by · m² square metre, an area unit

m² square metre, an area unit · mm millimetre, 0.001 metre · L litre, a volume unit · CNEA Comisión Nacional de Energía Atómica · NOA Noroeste Argentino Northwestern Argentina · g gram, 0.001 kilogram · = equals · × multiplied by · CAA Código Alimentario Argentino, the Argentine Food Code