UCLA credits Sidney Loeb and Srinivasa Sourirajan with the practical reverse-osmosis membrane announced in 1960. This is an attribution for a specific technological advance, not the invention of all membrane science. UV, reverse osmosis and distillation work by different mechanisms and have different operating requirements.
UCLA: University of California, Los Angeles. The institution named in the reverse-osmosis membrane history.
Five applications
1. Equipment selection: match a verified contaminant to a rated process.
2. Maintenance: track filters, lamps and service intervals.
3. Outage planning: identify electricity and pressure dependencies.
4. Water accounting: include waste and reject streams.
5. Troubleshooting: identify when a system must be taken out of service.
1. Identify the source water and the contaminant or organism of concern.
2. Obtain the relevant test result or official water notice.
3. Find equipment with independently supported performance for that exact problem.
4. Read feed-water limits, pressure, flow and power requirements.
5. Check whether pretreatment is required and how it will be maintained.
6. Draw the flow path, including treated water, reject water and any bypass.
7. Install and commission according to the manufacturer and applicable requirements.
8. Record service dates and measurable indicators such as pressure or lamp status where specified.
Reverse osmosis, ultraviolet light and distillation
Read the illustration’s labels
A
B
C
D
| Key | Small-print annotation |
|---|---|
| A | Practical method and reference · continued |
| B | 9. Retest or verify performance at the specified interval and after relevant failures. |
| C | 10. Stop relying on the unit when a critical operating condition cannot be met; use a verified safer source. |
| D | WORKED EXAMPLE AND MEASUREMENTS |
An RO unit with an assumed recovery of 25% would require 40 litres of feed to produce 10 litres of treated water, leaving 30 litres as reject. This is arithmetic for an illustrative assumption, not a typical rating for every unit. Use the actual equipment specification. UV treatment does not remove dissolved chemicals; distillation does not guarantee removal of every volatile contaminant.
In the drawing: Practical method and reference · continued; 9. Retest or verify performance at the specified interval and after relevant failures.; 10. Stop relying on the unit when a critical operating condition cannot be met; use a verified safer source.; WORKED EXAMPLE AND MEASUREMENTS
Limits and failure checks
A working light, clear output or normal taste is not proof that all hazards were removed. Home-built treatment needs validated performance, not visual resemblance to a commercial unit.
847 Reference library
Vi · the complete bug‐in guide
Plan a water carry by mass
A visual reading of the existing method and its evidence.
Read the illustration’s labels
10 litres
In the drawing: 10 litres 10 litres 10 litres
Ten litres Ten litres Ten litres
Three tenlitre containers hold approximately thirty kilograms of water together. Container mass adds to the load. Access, distance, steps and handling affect a workable plan.
Keep the closures clean and choose a source suitable for drinking. Record the number of trips and the clean storage available at the destination.
Terms in this reading
kg · Kilogram. A unit of mass equal to one thousand grams.
L · Litre. One cubic decimetre of volume, or one thousand millilitres.
Read the full method Earlier image gallery
Start with the household's known safe reserve and the current local supply information. Ask the water utility or emergency authority about distribution points. Avoid an unnecessary journey if help can be arranged through an established network.
Do not assume water is usable because it looks clear. Water affected by fuel or toxic chemicals cannot be made safe by ordinary boiling or disinfection. Use another source when such contamination is known or suspected. [R25]
Treat collection, treatment and storage as separate steps. Carry water in a suitable clean container, use a method appropriate to the identified problem and prevent recontamination afterwards. If the source or contaminant cannot be assessed, do not invent certainty from a home experiment.
Units and terms in this account
BY-SA Creative Commons Attribution-ShareAlike · UCLA University of California, Los Angeles · UV Ultraviolet Electromagnetic radiation with wavelengths shorter than visible violet light
RO Reverse osmosis · UV Ultraviolet Electromagnetic radiation with wavelengths shorter than visible violet light · % percent, parts per hundred