The related illustration appears earlier in this volume · page 1312
Collection specimen photograph. Steiermärkisches Landesmuseum Joanneum ‐ Herbarium GJO (custodian; photographer unlisted). Catalogue 0123142. Collection date 2021‐11‐03. Steiermärkisches Landesmuseum Joanneum ‐ Herbarium GJO. Image use follows http://creativecommons.org/licenses/by/4.0/.
GJO (collection code) · Universalmuseum Joanneum herbarium, Graz. Identifies the holding collection or programme in this specimen record.
River water: sensors, units and reliable records
Read the illustration’s labels
River measurements: from water to a dated record
A multiparameter sonde holds several sensors in one probe body.
The arrangement below explains functions, not a particular commercial device.
DATE / TIME
Dry recorder
Cable kept clear of strain
Sonde
Water flow
PROBE-END DETAIL
pH
SC
DO
Turbidity
Temp.
Sensor locations are schematic.
Guard openings let water reach
the measurement surfaces.
QUANTITY
UNIT / MEANING
Temperature
°C: degrees Celsius
Specific conductance (SC)
µS/cm at 25°C: microsiemens per centimetre
Acidity or alkalinity scale; no physical unit
Dissolved oxygen (DO)
mg/L: milligrams per litre of water
FNU or NTU, with the measurement method stated
RECORD THE CONDITIONS WITH THE READING
Site, date, local time, depth, calibration checks and sensor stability belong together.
Wait for the selected method’s stability criterion. There is no universal hold time.
A sonde reading alone cannot establish that water is safe to drink.
Keep the instrument and its calibration record together
The US Geological Survey’s multiparameter guidance, revised in June 2025, calls for sensor calibration or checks before field use. Follow the manufacturer’s warm-up instructions. Retain the standards, check results and instrument identity with the field record. A stable display does not by itself prove accurate calibration. [RD-WATER1]
Conductance describes dissolved ions
Specific conductance reflects the ability of dissolved ions to carry current. Temperature affects that response, so values commonly refer to 25°C. Keep the compensation convention with the result. A change can indicate a change in dissolved constituents, but it does not identify which substance caused it. [RD-WATER2]
Turbidity needs its method as well as its number
Turbidity measures an optical response to suspended material. FNU means formazin nephelometric unit; NTU means nephelometric turbidity unit. Common FNU instruments use near-infrared light and a 90° detector, while common NTU methods use white light with a 90° detector. Results from different methods are not automatically interchangeable. Retain the instrument method, range and any dilution with the reported value. [RD-WATER3]
These measurements support observation of a water body. Drinking-water decisions also require the appropriate microbiological and chemical assessment. The drawing is a measurement reference, not a certificate for an untested instrument or water source.
Units and terms in this account
FS United States Forest Service, in the specimen record
pH A logarithmic measure of hydrogen-ion activity · SC Specific conductance; conductivity referred to a stated temperature · DO Dissolved oxygen in water · FNU Formazin nephelometric unit; turbidity method must be stated · NTU Nephelometric turbidity unit · °C degree Celsius, a temperature unit
US United States · °C degree Celsius, a temperature unit · FNU Formazin nephelometric unit; turbidity method must be stated · ° degree, an angle unit
