River water: sensors, units and reliable records

Read the illustration’s labels

River measurements: from water to a dated record

A multiparameter sonde holds several sensors in one probe body.

The arrangement below explains functions, not a particular commercial device.

DATE / TIME

Dry recorder

Cable kept clear of strain

Sonde

Water flow

PROBE-END DETAIL

pH

SC

DO

Turbidity

Temp.

Sensor locations are schematic.

Guard openings let water reach

the measurement surfaces.

QUANTITY

UNIT / MEANING

Temperature

°C: degrees Celsius

Specific conductance (SC)

µS/cm at 25°C: microsiemens per centimetre

Acidity or alkalinity scale; no physical unit

Dissolved oxygen (DO)

mg/L: milligrams per litre of water

FNU or NTU, with the measurement method stated

RECORD THE CONDITIONS WITH THE READING

Site, date, local time, depth, calibration checks and sensor stability belong together.

Wait for the selected method’s stability criterion. There is no universal hold time.

A sonde reading alone cannot establish that water is safe to drink.

Keep the instrument and its calibration record together

The US Geological Survey’s multiparameter guidance, revised in June 2025, calls for sensor calibration or checks before field use. Follow the manufacturer’s warm-up instructions. Retain the standards, check results and instrument identity with the field record. A stable display does not by itself prove accurate calibration. [RD-WATER1]

Conductance describes dissolved ions

Specific conductance reflects the ability of dissolved ions to carry current. Temperature affects that response, so values commonly refer to 25°C. Keep the compensation convention with the result. A change can indicate a change in dissolved constituents, but it does not identify which substance caused it. [RD-WATER2]

Turbidity needs its method as well as its number

Turbidity measures an optical response to suspended material. FNU means formazin nephelometric unit; NTU means nephelometric turbidity unit. Common FNU instruments use near-infrared light and a 90° detector, while common NTU methods use white light with a 90° detector. Results from different methods are not automatically interchangeable. Retain the instrument method, range and any dilution with the reported value. [RD-WATER3]

These measurements support observation of a water body. Drinking-water decisions also require the appropriate microbiological and chemical assessment. The drawing is a measurement reference, not a certificate for an untested instrument or water source.

Units and terms in this account

FS United States Forest Service, in the specimen record

pH A logarithmic measure of hydrogen-ion activity · SC Specific conductance; conductivity referred to a stated temperature · DO Dissolved oxygen in water · FNU Formazin nephelometric unit; turbidity method must be stated · NTU Nephelometric turbidity unit · °C degree Celsius, a temperature unit

US United States · °C degree Celsius, a temperature unit · FNU Formazin nephelometric unit; turbidity method must be stated · ° degree, an angle unit