A material schedule should identify the job of each item. Frame members carry loads; connectors transfer those loads between members; face panels form floors or boundaries; nets and slides create particular play routes. Their interfaces matter as much as the individual pieces. A replacement chosen only for a matching colour or outline can leave its connection, weather exposure or intended function unresolved.

Enclosed slide and attachment points

The tubular-slide photograph shows a different slide enclosure from the open-slide view. Keep the product and attachment records for the arrangement actually installed. Inspection access must allow the maintainer to see the joint at the pod, the supports and the exit area. The illustration does not establish that an attachment designed for one slide can support another.

Stacked modules and their shared joint

In the stacked arrangement, loads from the upper module pass through the connection to the lower module and then to the ground. The shared interface deserves its own drawing and record. A total count of timber lengths does not describe that joint, and a repeated panel shape does not show whether the two modules have identical forces or fittings.

For wood, specify species or product, stress grade where relevant, moisture condition, dimensions, protection and fastening system. The Forest Products Laboratory’s Wood Handbook treats moisture, mechanical properties, grading, fastenings and deterioration as distinct subjects. A decorative finish is not a substitute for those material decisions. [RD-I-SPA-E3]

The United States Consumer Product Safety Commission’s public-playground handbook addresses user age, access, falls, protective surfacing, entrapment, protrusions and maintenance. Its guidance helps identify separate issues to review; it does not certify these supplied designs. Record the installed equipment, its instructions, inspection findings and repairs so that deterioration or a changed part can be traced. Apply the requirements of the actual project location. [RD-I-SPA-H06]

SPA Complex: from the whole frame to its joints

The SPA Complex perspective shows a broad dome-like frame with a timber-coloured upper lattice, dark lower framing and an opening at the crown. The next structural view shows the same general arrangement without the finished floor, exposing the downward supports. These are supplied design views, not evidence of a completed building or a construction sequence. [RD-I-SPA-E1]

The structural view exposes the supporting members

Read the view by following an individual member to the joint at each end, then following its supporting neighbours toward the base. Changes near the entrance, lower edge or crown identify places where the repeated pattern is interrupted. Those locations need their own matching details; a general dome silhouette does not identify every connection.

The supplied view has a cut-off heading at the right edge of the file. It is preserved as supplied. It does not show an exploded installation sequence, temporary bracing or the order of lifting. An erection plan must identify what supports each incomplete stage. The drawing’s spatial arrangement helps explain relationships, while its missing installation information remains separate.