Read the boundary before counting stored energy
12.8 V × 20 Ah
Read the illustration’s labels
NAMEPLATE
256 Wh
USABLE DRAW
204.8 Wh
AT THE LOADS
174.08 Wh
× 0.80
× 0.85
174.08 Wh ÷ 110 Wh/day ≈ 1.58 days in this worked example.
The two delivery factors are assumptions. Measure the actual system.
× 0.80 × 0.85
CONTEMPORARY TEACHING DRAWING · Parts and dimensions are explained in the adjacent text. A nominal rating of 12.8 volts and twenty ampere-hours gives 256 watt-hours. Under the example’s eighty per cent usable fraction, 204.8 watt-hours are available at the storage boundary. An assumed eighty-five per cent delivery factor leaves 174.08 watt-hours at the devices. A service of 110 watt-hours per day would therefore last about 1.58 example days. Two days require 220 watt-hours at the devices. Dividing by both factors gives a nominal requirement of 323.53 watt-hours, or about 25.28 ampere-hours at 12.8 volts.
Electrochemical impedance spectroscopy applies a small alternating disturbance over a series of frequencies. Its impedance plots do not directly state how many watt-hours a battery will deliver. For that question, record terminal voltage and current over time to a defined cutoff. Temperature, discharge rate, age and cutoff belong beside the result. A nominal label and a measured usable capacity are different records.
The store, the allowable draw and the delivered service.
Gamry Instruments · electrochemical impedance spectroscopy
Units and terms in this account
V volt, electrical potential difference · × multiplied by · Wh watt-hour, energy · ≈ approximately equal to · ÷ divided by
