This table transcribes every row of the assembly sheet’s schedule in its original order. The first column locates a row, the second names the item, and the third gives its quantity. The connector labels on the placement drawing refer to the second column. [RD-I-SPA-E1]
| Schedule position | Designation on sheet 61 | Quantity |
|---|---|---|
| 1 | Matrix | 1 |
| 2 | Connector No. 0.1 | 1 |
| 3 | Connector No. 1 | 8 |
| 4 | Connector No. 1.1 | 1 |
| 5 | Connector No. 1.2 | 1 |
| 6 | Connector No. 2 | 4 |
| 7 | Connector No. 2.1 | 4 |
| 8 | Connector No. 2.2 | 1 |
| 9 | Connector No. 2.3 | 1 |
| 10 | Connector No. 3 | 5 |
| 11 | Connector No. 3.1 | 5 |
| 12 | Connector No. 4 | 5 |
| 13 | Connector No. 5 | 4 |
| 14 | Connector No. 5.1 | 1 |
| 15 | Connector No. 6 | 4 |
| 16 | Connector No. 6.1 | 4 |
| 17 | Connector No. 6.2 | 1 |
| 18 | Connector No. 6.3 | 1 |
| 19 | Connector No. 7 | 5 |
| 20 | Connector No. 7.1 | 5 |
| 21 | Connector No. 8 | 8 |
| 22 | Connector No. 9 | 10 |
| 23 | Connector No. 10 | 10 |
| 24 | Connector No. 11 | 5 |
| 25 | Connector No. 12 | 5 |
| 26 | Connector No. 13 | 10 |
| 27 | Connector No. 14 | 5 |
| 28 | Connector No. 15 | 5 |
| 29 | Connector No. 15.1 | 5 |
| 30 | Connector No. 16 | 5 |
The 29 connector designations total 129 complete connectors. Matrix is a separate entry with quantity 1 and an unconfirmed meaning. Counting it as a connector would change the meaning of the source rather than merely add its numbers.
Reconcile the schedule with the delivered parts
Keep each connector type under its own label and compare the physical count with the row for that exact designation. Record receipt, condition, revision and any unresolved difference. A missing No. 6.2 is not resolved by an extra No. 6, and a matching count does not prove that the two parts have the same geometry. Check the placement drawing and the applicable detail before treating a part as interchangeable.
The schedule is an inventory of named connector assemblies. It is not a list of every plate, bolt, washer, timber member or foundation component. Those quantities require their own linked drawings and schedules. Retain the complete assembly sheet and Connector No. 1 detail with this table so the identifiers lead to something the reader can inspect.
Quadrosphere: reading the 7 × 7 m material estimate
The supplied Quadrosphere sheet combines an exterior illustration with a material estimate for a 7 × 7 m concept. The illustration shows the intended appearance, while the entries beneath it record lengths, areas, thicknesses and component counts. Those are different quantities and must remain attached to their own material descriptions. [RD-I-SPA-E1]
The title’s 7 × 7 m describes a stated overall concept size. Its 49 m² bounding square is a geometric area, not a measured usable floor area or a complete cladding take-off. The curved enclosure, openings and finishing layers require their own measurements. The source gives no complete cutting list, connection design or foundation drawing.
Turn a source length into a purchase quantity
The steel entry is 156 m. A cutting plan must allocate the required member lengths to the available stock, allowing for the saw cut, end preparation and unusable remnants. Merely dividing total required length by a supplier’s stock length cannot establish that all pieces will fit. Keep net design length, waste allowance and rounded purchase quantity as separate entries, with the reason for each adjustment. The source does not specify a universal waste percentage.
The next table reproduces all thirteen source entries. The two membrane rows each show 70 m², and the timber row explicitly gives a 50 × 50 mm section. Product selection and installation details remain separate questions.
Units and terms in this account
° degree, an angle unit
m metre, a length unit · × multiplied by · m² square metre, an area unit
m metre, a length unit · m² square metre, an area unit · mm millimetre, 0.001 metre · × multiplied by