Count the parts, price the purchases / continued
Words and units
ARS means Argentine peso; USD, United States dollar; EUR, euro. SVG means Scalable Vector Graphics. Millimetre is written mm; revolutions per minute is written rpm. Module is pitch diameter divided by tooth count. A ratio of twelve to one states the relation of input turns to output turns, not the efficiency. The model has not been physically built or loadtested for this edition.
Argentina · plan, build and record
Three kinds of number at one workbench
Numbers with three different jobs
A prediction, a reading and a derived result need separate records
| Kind of number | Example and interpretation |
|---|---|
| 1. Predict | Nominal 3 V and 330 Ω. I = V / R = 9.09 mA. Assume fixed resistance. |
| 2. Observe | Read voltage: 2.96 V. Isolated part: 327 Ω. Record range and time; keep the displayed digits. |
| 3. Derive | I = 2.96 / 327 A ≈ 9.05 mA. Calculated from readings: current was not measured. |
| Board layout | Holder and breadboard on a nominal 350 × 250 mm rectangle: 87,500 mm² = 0.0875 m². Measure the cut piece too. Area is not a fit check. The 250 mm depth is an illustrative layout, not a scaled mounting drawing. |
Original teaching diagram · stated examples, not recorded measurements
The board that does not yet exist
Take a proposed backing board measuring 350 × 250 mm. Multiplication gives an area of 87,500 mm², or 0.0875 m². That result is exact for the stated mathematical rectangle. It is not yet the measured area of a cut piece. A rounded corner, saw kerf or inaccurate ruler belongs to the physical object, not to the multiplication. The useful distinction is between an exact consequence of stated assumptions and an observation with limitations.
Prediction, observation and derivation
Write three columns before doing anything else. A prediction is what the model says should happen. An observation is what was actually read or seen, with the instrument and conditions. A derived result is calculated from those observations. For a nominal 330 Ω resistor at a nominal 3 V, the prediction is 9.09 mA. A later reading of 2.96 V and an earlier isolated resistance reading of 327 Ω imply 9.05 mA. That last number is an inference, not a current measurement. The resistance may also have changed between the two readings.
The unit is part of the claim
The letter m in mA means milli, one thousandth. The capital M in MΩ means mega, one million. A 1 MΩ input is 1,000,000 Ω; a 1 mΩ connection is 0.001 Ω. Confusing those prefixes changes the scale by a billion. Write 0.030 A or 30 mA consistently. In V = I × R, V denotes a potential difference in volts, I a current in amperes and R a resistance in ohms. The product I × R is multiplication, not an acronym called IR.
A procedure can be correct and still fail
Keep the result that disagrees
Suppose three repeated voltage readings are 2.96 V, 2.96 V and 2.97 V. Their agreement does not establish that the meter is accurate. A constant offset could affect all three. Conversely, a surprising reading is not automatically a bad instrument: the leads may touch different nodes. Copy the displayed digits first. Add interpretation afterwards. A crossed-out value should remain legible in a paper notebook, with the reason for changing it.
Argentina · materials and assembly
Units and terms in this account
mA milliampere, 0.001 ampere · = equals · V volt, electrical potential difference · Ω ohm, electrical resistance · A ampere, electric current · mm millimetre, 0.001 metre · mm² square millimetre · m² square metre, an area unit · ≈ approximately equal to · × multiplied by
mm millimetre, 0.001 metre · mm² square millimetre · m² square metre, an area unit · × multiplied by · Ω ohm, electrical resistance · V volt, electrical potential difference · mA milliampere, 0.001 ampere · A ampere, electric current · = equals
AA A standardized cylindrical battery size designation, not an acronym · DC Direct current · Ω ohm, electrical resistance · V volt, electrical potential difference · W watt, power · × multiplied by · DMM Digital multimeter, an instrument with selectable electrical measurement functions