The source offers a 100 × 50 mm rectangular hollow section with a wall-thickness range of 2 to 3 mm. The same outside dimensions and total length do not imply the same mass. Wall thickness changes the amount of steel along the whole member, as well as its structural behaviour. The project design must choose the specified section; a lower price is not evidence that a thinner wall is an acceptable substitute.

A transparent geometric comparison

For an ideal sharp-cornered hollow rectangle, the steel cross-sectional area is the outer width multiplied by outer depth, minus the corresponding inner rectangle. With dimensions in millimetres, convert the result to square metres before multiplying by length and density. Using the stated 156 m length and an assumed steel density of 7,850 kg/m³ gives the comparison below.

Assumed wall thicknessIdeal steel areaApproximate mass per metreApproximate mass for 156 m
2 mm584 mm²4.584 kg/m715 kg
3 mm864 mm²6.782 kg/m1,058 kg

This arithmetic assumes uniform thickness, sharp corners and the stated density. Real hollow sections have corner radii and manufacturing tolerances, so a supplier’s certified section mass is the appropriate purchasing value. Connectors, welds, coatings and other components are not included in these tube-only masses. The table explains why the source’s thickness range matters; it is not a structural capacity calculation.

The ordered length must come from the cutting plan and actual stock availability. The source gives no stock-bar order or cutting pattern. Keep any later allowance explicitly attached to the design and purchasing assumptions that produced it.

What the poster actually says

The Portuguese source is headed “Dome geodésico de madeira”, meaning a timber geodesic dome. The labels combine structure, insulation, enclosure and a floor build-up. Numbers 5 and 6 repeat a cork-based waterproofing description. Numbers 8 and 9 repeat a sprayed-cork finish description. Repetition on the poster is not evidence that two identical layers must be installed. Preserve the original in the gallery and use the transcription below to ask a precise product or assembly question. [E1]

Structure and enclosure perform different jobs

The frame carries forces through the members and joints. Insulation slows heat transfer. An air-control layer limits uncontrolled air movement. A water-control layer directs rain toward an outlet. A vapour-control layer changes the movement of water vapour by diffusion. Interior finish protects and completes the room. One product may perform more than one function, but that must be established from its specification and detailing. OSB means oriented strand board; XPS means extruded polystyrene.

XPS: Extruded polystyrene. A closed-cell plastic insulation material whose actual fire, moisture and load conditions must be checked from its product specification.

OSB: Oriented strand board. An engineered wood panel made from bonded strands arranged in layers; its grade and service conditions determine suitability.

Argentina · United States · European Union

1. Choose the indoor and outdoor conditions

Record the site, altitude, winter and summer conditions, intended occupancy, heating and cooling, wet activities and whether the building will be continuously occupied. Argentina includes humid subtropical, temperate, mountain and cold southern conditions. A single membrane position cannot be prescribed for all of them. In the United States and Europe, the same need to match assembly to climate applies. Determine product vapour resistance, rain exposure and drying direction before ordering the layer stack.

Functional cutaway. Product order and vapour resistance must suit the local climate and complete roof assembly.

1. Inner finish

Units and terms in this account

mm millimetre, 0.001 metre · × multiplied by · m metre, a length unit · kg kilogram, a mass unit · m³ cubic metre, a volume unit · mm² square millimetre