What the poster actually says

The Portuguese source is headed “Dome geodésico de madeira”, meaning a timber geodesic dome. The labels combine structure, insulation, enclosure and a floor build-up. Numbers 5 and 6 repeat a cork-based waterproofing description. Numbers 8 and 9 repeat a sprayed-cork finish description. Repetition on the poster is not evidence that two identical layers must be installed. Preserve the original in the gallery and use the transcription below to ask a precise product or assembly question. [E1]

Structure and enclosure perform different jobs

The frame carries forces through the members and joints. Insulation slows heat transfer. An air-control layer limits uncontrolled air movement. A water-control layer directs rain toward an outlet. A vapour-control layer changes the movement of water vapour by diffusion. Interior finish protects and completes the room. One product may perform more than one function, but that must be established from its specification and detailing. OSB means oriented strand board; XPS means extruded polystyrene.

XPS: Extruded polystyrene. A closed-cell plastic insulation material whose actual fire, moisture and load conditions must be checked from its product specification.

OSB: Oriented strand board. An engineered wood panel made from bonded strands arranged in layers; its grade and service conditions determine suitability.

Argentina · United States · European Union

1. Choose the indoor and outdoor conditions

Record the site, altitude, winter and summer conditions, intended occupancy, heating and cooling, wet activities and whether the building will be continuously occupied. Argentina includes humid subtropical, temperate, mountain and cold southern conditions. A single membrane position cannot be prescribed for all of them. In the United States and Europe, the same need to match assembly to climate applies. Determine product vapour resistance, rain exposure and drying direction before ordering the layer stack.

Functional cutaway. Product order and vapour resistance must suit the local climate and complete roof assembly.

1. Inner finish

Inside outside

2. Service space

3. Air-control layer

4. Frame + insulation

5. Sheathing

6. Water-control layer

7. Drainage / battens

8. Outer covering

The supplied poster repeats two labels. Its thirteen numbers are transcribed in the reading guide; they are not thirteen validated construction stages.

2. Draw one continuous line for each control function

On a section through wall, roof, floor and opening, draw an uninterrupted air-control line and a separate water-control line. Mark every seam, corner, penetration and change of material. The Building America air-barrier guidance emphasises continuous connections and sealed penetrations, with the air-control layer aligned with insulation. The teaching section here applies that principle to a faceted enclosure. It is not a tested proprietary dome assembly. [E4]

3. Make a junction sample

Build a small unoccupied sample containing two adjacent panels and part of an opening, using the proposed product system. Label the inside and outside. Demonstrate how the specified tapes, gaskets or membranes join at the corner, where a fastener penetrates and where water leaves the sill. Photograph each stage before the next layer covers it. Use the manufacturer’s permitted primer, substrate condition, overlap and curing instructions. A sample confirms workmanship and compatibility questions; it does not replace the assembly’s design review.

Units and terms in this account

mm millimetre, 0.001 metre · × multiplied by · m metre, a length unit · kg kilogram, a mass unit · m³ cubic metre, a volume unit · mm² square millimetre