CAN · Controller Area Network A shared digital message network through which electronic control units exchange data.
CAN High / CAN Low · Controller Area Network high and low signal lines Receivers read the voltage difference between these two signal conductors.
GPS · Global Positioning System A satellite‐based system used to determine a receiver’s position.
GSM · Global System for Mobile Communications The cellular system named on the bicycle security sheet.
SMS · Short Message Service The cellular text‐message service used to send an alert on the sheet.
LED · Light‐emitting diode A small semiconductor indicator shown on both electronic instruments.
USB · Universal Serial Bus An interface used for data or power. Micro and Type‐C identify connector families.
MHz · Megahertz One million cycles per second. The bicycle sheet gives cellular radio bands in this unit.
GND · Ground The local common reference or return in a circuit drawing.
TX / RX · Transmit and receive Labels for the send and receive pins of a serial interface.
TX: Transmit. On the serial-interface drawing TX and RX, receive, identify signal functions; the actual wiring still follows the device’s pin specification.
RST · Reset A pin that returns the controller to its starting state.
VIN · Voltage input The marked supply‐input terminal on the illustrated controller board.
AREF · Analog reference The reference pin for the controller’s analog‐to‐digital conversion.
A0–A7 / D0–D13 · Analog and digital pin designations The pin number identifies a controller connection, not a voltage or command.
SIM800L · Cellular module model SIM800L A product designation on the bicycle sheet, identifying the module shown.
°C · Degrees Celsius A unit of temperature used in the operating ranges on the source sheets.
DC · Direct current Current flows in one direction in the isolated teaching circuit.
V · Volt Unit of potential difference between two points. In circuit equations the letter can also denote voltage.
mA · Milliampere One thousandth of an ampere, used for the demonstration current.
What becomes of the missing voltage?
Read the illustration’s labels
A
B
C
D
E
F
G
H
I
J
K
L
M
| Key | Small-print annotation |
|---|---|
| A | A fault can become measurable only while current is flowing. |
| B | One source and two voltage drops |
| C | 0.65 V |
| D | 4.35 V |
| E | V |
| F | V |
| G | 15 Ω |
| H | 100 Ω |
| I | 5.00 V |
| J | Series current ≈ 43.48 mA |
| K | DRAWING |
| L | ENLARGED DETAIL / OPEN THE COMPLETE PLATE |
| M | The teaching resistor representing a poor connection drops about 0.65 volt under the stated load. |
Motor vibration analyzer · Rizwan Khan, printed creator credit. Supplied by ZeusC.
In the drawing: A fault can become measurable only while current is flowing.; One source and two voltage drops; 5.00 V; 15 Ω 100 Ω; V V; 0.65 V 4.35 V; Series current ≈ 43.48 mA; DRAWING The teaching resistor representing a poor connection drops about 0.65 volt under the stated load.; ENLARGED DETAIL / OPEN THE COMPLETE PLATE
A workshop notebook begins with a complaint. It becomes reproducible when another person can see precisely where each reading came from. DENSO’s chargingsystem guidance distinguishes the positive and negative sides of a circuit when checking voltage drop. The distinction is useful in an Argentine workshop as in any other. A reading belongs to two named points, an instrument and a state of load. A continuity signal with the power removed records a different test. It may establish that there is a path while revealing very little about the voltage consumed at a poor joint when current flows.
Model the distinction on an isolated bench. An ideal 5.00volt source feeds a 100ohm load through an added 15ohm resistor. Together they present 115 ohms. Divide the supply voltage by that total to obtain about 43.48 milliamperes. A voltmeter would indicate about 0.65 volt across the added resistor and 4.35 volts across the load. The two readings add back to the supply voltage within rounding. Record where the red and black probes would be placed and which operation was calculated. ZeusC’s vibrationanalyzer sheet follows a different physical signal. Its relevance lies in the same discipline of recording the sensor, its location and the operating condition beside a result.
Electrical instruments: terms and units
| Term | Meaning in this section |
|---|---|
| V | Volt Unit of potential difference between two points. In circuit equations the letter can also denote voltage. |
| Ω | Ohm Unit of resistance. Higher resistance reduces current at a fixed source voltage. |
| mA | Milliampere One thousandth of an ampere, used for the demonstration current. |
| ≈ | Approximately equal The displayed measurement or calculated result has been rounded. |
| IPS | In-plane switching A display-panel technology used in the vibration analyzer illustration. |
| LCD | Liquid-crystal display The technology used for the analyzer screen. |
| PCB | Printed circuit board The board carrying the instrument’s electronic components and interconnections. |
| Li-Po | Lithium polymer The rechargeable battery type named on the analyzer source. |
| mAh | Milliampere-hour A unit of battery charge capacity. It combines current and time. |
| A | Ampere Unit of electric current, the rate of charge flow. |
| LED | Light-emitting diode A small semiconductor indicator shown on both electronic instruments. |
| USB | Universal Serial Bus An interface used for data or power. Micro and Type-C identify connector families. |
| IEPE | Integrated electronics piezoelectric A type of powered piezoelectric sensor interface for vibration measurement. |
| RPM | Revolutions per minute A measure of rotational speed at the tachometer input. |
| SD | Secure Digital A family of memory cards. The sheet shows a microSD slot for data logging. |
| FFT | Fast Fourier transform A numerical method for separating a sampled signal into frequency components. |
| RMS | Root mean square A measure of the effective magnitude of a varying signal, used in the vibration readout. |
| ADC | Analog-to-digital converter The stage that represents a measured analog signal as digital values. |
| COM / NO / NC | Common, normally open and normally closed Relay contact labels. Normal describes the relay’s unenergized state. |
| NC (input pins) | No connection A reserved or unused connector pin in the sensor diagrams, distinct from a normally closed relay contact. |
| GND | Ground The local common reference or return in a circuit drawing. |
| Hz / kHz | Hertz and kilohertz Cycles per second and thousands of cycles per second. |
| mm/s | Millimetres per second A vibration velocity unit used on the analyzer. |
| mm | Millimetre One thousandth of a metre, used in dimensions and displacement readings. |
| P-P | Peak to peak The total excursion from the smallest to the largest signal value. |
| kS/s | Kilosamples per second A sampling rate in thousands of measured values per second. |
| g (acceleration) | Standard gravity A unit used to express the analyzer’s acceleration range, approximately 9.81 metres per second squared. |
| g (mass) | Gram A unit of mass, used for the analyzer’s weight specification. |
| °C | Degrees Celsius A unit of temperature used in the operating ranges on the source sheets. |
| DC | Direct current Current flows in one direction in the isolated teaching circuit. |
Where the splice grips the conductor
Read the illustration’s labels
Butt splice: conductor, barrel and insulation
LONGITUDINAL SECTION
Insulating jacket
Compressed metal barrel
Conductor strands
Opposed wire ends
Each conductor enters from its own end.
The barrel transfers load through the compressed metal contact.
Insulation position, strand condition and the specified tool matter.
Schematic interpretation of NASA figure 19-28; no crimp size or rating is implied.
Open NASA’s original butt-splice figure. · page 1537
A harness can look orderly from the outside and still contain a poor joint. The United States National Aeronautics and Space Administration (NASA) publishes workmanship requirements for cables, harnesses and wiring. In its crimping standard, figure 19–28 illustrates a butt splice. The named object matters. Two stripped conductor ends enter a metal barrel from opposite directions. Compression of the metal makes and retains contact. Positioning the conductor and placing the insulation correctly are separate questions, so a general note saying that a joint looks tidy would leave much of the inspection undocumented.
The conductor strands, crimp barrel and insulating jacket have different functions. The barrel retains the stripped conductors through compressed metal contact. Insulation supports and protects the wire outside that contact. Visible strand position is an observation; a pull test requires a defined sample, fixture and acceptance criterion. NASA directs readers to manufacturer specifications for barrel selection and inspection. The matching vehicle manufacturer’s service information governs an actual automotive harness repair.
National Aeronautics and Space Administration · Standard approved 30 June 2016, displayed copy at Change 4 The image shows a crimped barrel on opposed conductor ends. The workmanship requirements and their scope are on the surrounding page of the agency document. United States government technical standard. Original embedded figure from page 87.
Units and terms in this account
LED Light-emitting diode · USB Universal Serial Bus, the wired interface used for data and device power · GND Ground, the circuit reference node
RST Reset, a controller signal · VIN Voltage input in the controller-board drawing · AREF Analog reference, the controller's conversion-reference pin · °C degree Celsius, a temperature unit · V volt, electrical potential difference · Ω ohm, electrical resistance · mA milliampere, 0.001 ampere · ≈ approximately equal to
V volt, electrical potential difference · Ω ohm, electrical resistance · mA milliampere, 0.001 ampere · ≈ approximately equal to
IPS In-plane switching, a display-panel technology · PCB Printed circuit board, the board carrying conductor tracks and electronic components · USB Universal Serial Bus, the wired interface used for data and device power · IEPE Integrated electronics piezoelectric, a powered sensor interface · RPM Revolutions per minute, a rotation speed unit · SD Secure Digital, a memory-card family · RMS Root mean square, a measure of a varying signal’s effective magnitude · COM Common, the usual label for the meter’s common-reference lead socket · GND Ground, the circuit reference node · °C degree Celsius, a temperature unit · Ω ohm, electrical resistance · ≈ approximately equal to
IPS In-plane switching, a display-panel technology · PCB Printed circuit board, the board carrying conductor tracks and electronic components · USB Universal Serial Bus, the wired interface used for data and device power · IEPE Integrated electronics piezoelectric, a powered sensor interface · RPM Revolutions per minute, a rotation speed unit · SD Secure Digital, a memory-card family · RMS Root mean square, a measure of a varying signal’s effective magnitude · COM Common, the usual label for the meter’s common-reference lead socket · GND Ground, the circuit reference node · °C degree Celsius, a temperature unit · Ω ohm, electrical resistance · ≈ approximately equal to · NASA National Aeronautics and Space Administration
NASA National Aeronautics and Space Administration · STD Standard, a technical-document designation · DC Direct current · V volt, electrical potential difference · mA milliampere, 0.001 ampere · A ampere, electric current · W watt, power · = equals