One resistor: current and voltage
Read the illustration’s labels
One load, one complete path
Ideal values: 3.0 V source and 330 Ω resistance
+
−
3 V nominal
330 Ω
A
B
9.09 mA
Calculation
Result
I = 3 / 330
0.00909 A
P = 3² / 330
0.0273 W
Part rating used
At least 0.25 W
In the drawing: One load, one complete path; Ideal values: 3.0 V source and 330 Ω resistance; + −; 3 V nominal; 330 Ω A B; 9.09 mA; Calculation Result; I = 3 / 330 0.00909 A; P = 3² / 330 0.0273 W; Part rating used At least 0.25 W
Switch off and remove cells before changing connections.
OHM: OpenStax, Rice University: Ohm’s law
OHM · source
UNITED STATES United States: measurement and fault finding
Voltage is measured across two points
Resistance is measured only after power is removed and parallel paths are isolated
Read the illustration’s labels
3 V nominal
330 Ω
DC V: -3.00
COM
V / Ω
+ −
A b
With probes reversed, the signed reading reverses. Keep the named reference points in the record.
In the drawing: 3 V nominal; 330 Ω; DC V: -3.00; COM V / Ω
Illustrated meter shows reversed voltage probes: red on the lower-potential side, black on the higher- potential side. Never place a current input across a battery.
Ohm, Gauss and Kirchhoff in a low-energy workshop
| Information from the source panel |
|---|
| Measure voltage across, resistance with power removed |
| Use a fault table instead of random rewiring |
| Power matters even when the resistance calculation is correct |
| COM: Common, the usual label for the meter’s common-reference lead socket. |
Units and terms in this account
COM Common, the usual label for the meter’s common-reference lead socket
V volt, electrical potential difference · Ω ohm, electrical resistance · mA milliampere, 0.001 ampere · A ampere, electric current · W watt, power · = equals
DC Direct current · COM Common, the usual label for the meter’s common-reference lead socket · V volt, electrical potential difference · Ω ohm, electrical resistance