UNITED STATES Measure voltage across, resistance with power removed
Voltage is measured across two points
Resistance is measured only after power is removed and parallel paths are isolated
Read the illustration’s labels
3 V nominal
330 Ω
DC V: -3.00
COM
V / Ω
Open the complete related drawing · page 1612
+ −
A b
With probes reversed, the signed reading reverses. Keep the named reference points in the record.
In the drawing: 3 V nominal; 330 Ω; DC V: -3.00; COM V / Ω
A digital multimeter combines several instruments, but its connections depend on the function selected. For voltage, place the probes across the two points being compared. In this small circuit, put the black probe at node B and the red probe at node A, with the meter set to an appropriate directcurrent voltage range. If the meter is manualranging, choose a range above the expected value. Follow the actual meter's instructions.
For resistance, remove the cells and isolate the component from parallel paths. The meter supplies its own small test signal. An externally powered circuit can give a false reading or damage the instrument. A resistor left in a network may be measured together with other paths, so the displayed number may not be the resistor's own value.
Current measurement normally requires the meter to become part of the circuit path. A currentinput connection placed directly across a battery can create a short circuit. For this beginner bench, keep the red lead in the voltage/resistance socket and derive current from the measured resistor voltage and resistance. Mark the unused current socket on the workshop sketch.
Record the meter model, selected range, lead sockets and displayed units. A reading of 9.1 mA means 0.0091 A; a reading of 9.1 A is one thousand times larger. The prefix m means milli, one thousandth, in this unit. Unit errors are often more consequential than the last digit on a display.
METER_V: Adafruit: multimeters, voltage
METER_R: Adafruit: multimeters, resistance
COM: Common, the usual label for the meter’s common‐reference lead socket.
METER_V · source METER_R · source
UNITED STATES Use a fault table instead of random rewiring
Find a fault with one controlled change
Record the observation before replacing a part
| Observation | Next check with the stated small circuit |
|---|---|
| No resistor voltage | Check holder voltage and switch position |
| Holder has voltage | Remove cells; trace each named node |
| Resistor seems bypassed | Check whether both leads share one group |
| Reading changes when touched | Inspect loose contacts with power removed |
| After repair | Repeat the same voltage and resistance checks |
For a teaching fault, remove one jumper with the cells removed. Do not create a battery short to demonstrate a failure.
A symptom can have several causes. Preserve the original connection list and change one thing at a time.
If the measured voltage across the resistor is near zero, first check whether the source is present at the holder leads with the switch in the intended position. Then remove the cells and compare the connection list with the actual board. An open switch, reversed or depleted cells, a loose jumper and two leads inserted in the same node are different faults. The observation alone does not identify which one occurred.
Change one thing at a time. Record the original arrangement before moving a wire, especially if the circuit once worked. After a change, repeat the same measurement at the same named points. If several wires are moved at once, an improvement may occur without revealing which change mattered.
The final record should identify the symptom, test, observation, inferred cause, repair and verification. “It works now” is incomplete. A useful verification might state that the measured resistor voltage returned to the expected range and remained stable when the leads were gently checked for a loose fit. Store the final connection list with the diagram.
UNITED STATES Power matters even when the resistance calculation is correct
Correct arithmetic still needs a suitable component
Power rises with the square of voltage when resistance is unchanged
Read the illustration’s labels
The 24 W comparison is a calculation only.
A 0.25 W classroom resistor is not suitable for a 24 W load. Voltage,
power rating and operating conditions all matter.
A
B
C
D
E
F
G
H
I
J
K
L
| Key | Small-print annotation |
|---|---|
| A | Paper case |
| B | Current |
| C | Resistor power |
| D | 3 V / 330 Ω |
| E | 9.09 mA |
| F | 0.0273 W |
| G | 6 V / 330 Ω |
| H | 18.18 mA |
| I | 0.1091 W |
| J | 12 V / 6 Ω |
| K | 2 A |
| L | 24 W |
OHM: OpenStax, Rice University: Ohm’s law
OHM · source
Units and terms in this account
DC Direct current · COM Common, the usual label for the meter’s common-reference lead socket · V volt, electrical potential difference · Ω ohm, electrical resistance · mA milliampere, 0.001 ampere · A ampere, electric current
W watt, power · V volt, electrical potential difference · Ω ohm, electrical resistance · mA milliampere, 0.001 ampere · A ampere, electric current