A ratio alone does not establish efficiency, load capacity or whether the mechanism will resist being driven backwards. Tooth geometry, lead angle, lubrication, material and friction matter. Do not describe every worm gear as selflocking. If holding a load is required, specify and verify a suitable holding arrangement instead of relying on an untested assumption.
Use a paper ratio wheel for the first demonstration. Divide a 210 millimetre diameter card disk into 42 labelled sectors and move a pointer by one sector for each counted input turn. This is a counting model, not a meshing worm gear. It needs one disk, one pointer, one centre pin, a backing board and a tally sheet.
BOOK IV / ARGENTINA · UNITED STATES · EUROPEAN UNION A stop and a shell are part of the mechanism
The shell must clear the whole motion
Check links, tubing, heads, stops and service access
Removable cover and access boundary
Wide soft stop
Swept envelope
A joint stop limits movement by contact between two parts. If a force at the fingertip produces a moment about the pivot, the stop must react that moment through its own distance from the pivot. A very short stop radius can produce a large contact force. The stop’s visible size is therefore not enough to judge its adequacy.
A shell must leave room for the entire swept path, not merely for the finger in one pose. Trace the linkage at several positions on transparent paper and combine the outlines. Add space for fastener heads, washers, tubing bends and removal of the pin. A part that can move but cannot be serviced is a poor workshop design.
Draw the access opening as carefully as the outer shape. For the demonstration, use a removable card cover with two tabs and leave the joint visible during testing. Keep wiring and tubing outside the moving envelope. Do not fit this shell to a human limb; comfort, skin contact, control and clinical fitting introduce requirements that the bench mechanism has not addressed.
Acceptance is a measured statement
Keep raw observations, units and decisions together
| Check | Acceptance record |
|---|---|
| 01 | Defined motion range |
| 02 | Ten slow unloaded cycles |
| 03 | Faults and interventions |
| 04 | Light foam block, mass recorded |
| 05 | Repair made and repeated trial |
| 06 | No wearable or load-rating claim |
In the drawing: 01 Defined motion range; 02 Ten slow unloaded cycles; 03 Faults and interventions; 04 Light foam block, mass recorded; 05 Repair made and repeated trial; 06 No wearable or load-rating claim