The related illustration appears earlier in this volume · page 2516
Cold-air chamber and counted card parts
No fuel connection; three bottle caps are position indicators
| Materials, quantities and record |
|---|
| Part · Count · Chosen size / mm |
| Carton and top · 1 + 1 · 400 x 300 x 150 / 400 x 300 |
| Card rings · 2 · Outside 140 / inside 90 |
| Chamber strip · 1 · 450 x 35, 10 overlap |
| Reinforcing pads · 4 · 50 x 50 |
| Bottle-cap indicators · 3 · About 30 diameter |
| Guarded fan · 1 · 50 x 50 x 11 |
| Wrap strip into chamber |
Use one 400 × 300 × 150 millimetre carton with a removable lid, one 400 × 300 millimetre stiffcard top, two card rings with outside diameter 140 millimetres and inside diameter 90 millimetres, one 450 × 35 millimetre card strip, four 50 × 50 millimetre reinforcing pads and three 30 millimetre bottle caps. The caps represent control positions only. Add one complete 50 millimetre guarded USB fan, its four supplied screwandnut sets, one intact compatible 5 volt supply, six tissue flags, two metres of tape and 20 millilitres of PVA adhesive.
Mark the ring centre at least 100 millimetres from every edge. Cut the two rings and wrap the strip around a temporary cylindrical former to make a shallow annular chamber. Join the strip ends with a 10 millimetre overlap. Fit one ring above and one below, leaving a large labelled inlet on the side. This is a visible airflow chamber, not a scaled gas burner.
Make a mounting panel for the fan using its actual 40 × 40 millimetre hole spacing. Reinforce the card on both sides and install both guards. Route its cable through a smooth opening with slack and strain relief. Keep the complete USB connector; do not expose or splice conductors for this model. Place tissue flags outside the guards and away from the fan blades.
Make the top and side panel removable with tape hinges and tabs. Mark the three bottle caps “position indicators, no valves.” Before applying power, check that every loose piece is retained and that the fan’s
guards are clear. Use only the manufacturer’s intended low-voltage supply arrangement. Stop the model if a flag detaches, the fan rubs or a cable becomes warm.
Cold-model commissioning
Keep raw observations, units and decisions together
Read the illustration’s labels
01
Guards and cables retained
02
Openings clear
03
Flags observed at fixed points
04
Power off before baffle change
05
Access panel removal checked
06
No combustion or gas test
In the drawing: 01 Guards and cables retained; 02 Openings clear; 03 Flags observed at fixed points; 04 Power off before baffle change; 05 Access panel removal checked; 06 No combustion or gas test
A commissioning record asks whether the assembled object performs its intended limited task. For the coldair model, the result is visible air movement at defined points, secure guards and removable access panels. It is not a flame test, gasleak test or proof of a combustion design. Write that scope at the top of the record.
Run the fan with all intended openings unobstructed and sketch the six tissueflag directions. Switch off before changing a baffle. Repeat with the baffle in a second position and note any change. A tissue flag gives a qualitative indication; it is not a calibrated airflow meter. Its length, stiffness and location influence its movement.
Check service access with the power disconnected. Remove the side panel, identify each fastener and show how the fan could be replaced without tearing the enclosure apart. Count the retained screws at the end. A lost screw inside a rotating mechanism is a fault, even if the model still appears to run.
For a real appliance quotation, ask the installer to identify what is included: compatible appliance, supply connection, isolation, ventilation, commissioning and documentation. Record the premises and fuel. A price without those details cannot be compared fairly with another quotation.
Units and terms in this account
USB Universal Serial Bus, the wired interface used for data and device power · PVA Polyvinyl acetate, the polymer in the specified white card or wood adhesive · × multiplied by