Read the illustration’s labels

A repeatable inspection is part of the model

Fault found? Stop,

disconnect, record the

cause, repair, then repeat

the same observation.

A

B

C

D

E

F

G

H

I

J

K

L

M

N

O

P

Q

R

S

T

KeySmall-print annotation
ACold-air demonstration only: six numbered observation stations
B1Disconnect
C2Run trial A
D3Disconnect
E4Run trial B
FCheck guards and parts
GRecord six flag directions
HMove one baffle
ICompare the same flags
J6
K5
LStation
MTrial A
NTrial B
OChanged?
P1 to 6
QDirection / still
RDirection / still
SWrite observation
TFlags show movement qualitatively. They do not measure air volume, gas tightness or combustion performance.

Give the completed model a repeatable inspection routine. Its purpose is to show an air path with an intact, guarded low-voltage fan and tissue indicators. Do not add fuel, a heater or a flame. A successful airflow observation does not establish combustion performance, a gas seal or suitability for cooking.

Before power: place the carton on a dry stable bench. Check both fan guards, retained screws, the removable panel and every tissue flag. Route the complete cable through the smooth opening without strain. Inspect the intact connector and use the compatible supply specified for the fan. Keep scissors, loose washers and offcuts out of the enclosure.

Mark six observation stations in the drawing: inlet, beside the fan outlet, chamber entry, chamber opposite the entry, top opening and room side of the outlet. Keep each indicator outside the guards and clear of blades. Number the flags and record their positions, lengths and material. An indicator that is changed between trials also changes the test.

Trial A: run the model with its normal openings clear. Record which flags move and sketch their direction. Switch off, disconnect and wait for the fan to stop before moving the removable baffle. Trial B: repeat with the second baffle position. Leave the fan supply and flag positions the same. Write what changed and what stayed the same. Do not treat an unmoving flag as a measured zero flow.

If a flag comes loose, the fan rubs, a guard shifts or the cable becomes warm, stop and disconnect. Find the cause before repeating the observation. Record the fault, repair and retest as three separate entries. The drawing shows the decision order, not an automatic protection system.

At the end, disconnect power, remove and count the six indicators, inspect for loose parts, and store the cable without tight bends. Keep the original fan instructions with the model. Argentina first, then the United States and European Union: record the locally purchased fan and approved supply as complete components in the regional bill, with a date and supplier. The same record can follow a model to another country without assuming that a plug, mains voltage or approval is interchangeable.