Fit limits and measurement uncertainty answer different questions

Read the illustration’s labels

Hole: 10.00 to 10.10 mm

Shaft: 9.90 to 9.95 mm

CLEARANCE LIMITS

Minimum 0.05 mm; maximum 0.20 mm.

RESULT WITH UNCERTAINTY

9.94 ± 0.03 mm spans 9.91 to 9.97 mm.

In the drawing: Hole: 10.00 to 10.10 mm; Shaft: 9.90 to 9.95 mm; CLEARANCE LIMITS; Minimum 0.05 mm; maximum 0.20 mm.; RESULT WITH UNCERTAINTY; 9.94 ± 0.03 mm spans 9.91 to 9.97 mm.

9.90 9.91 9.92 9.93 9.94 9.95 9.96 9.97 9.98

Green = drawing limits; red = stated measurement interval. Units: mm.

Original teaching drawing · Numerical examples are invented

Hypothetical fit limits and one uncertain observation. The section sketch exaggerates clearance for clarity. The shaded measurement interval crosses the upper shaft limit; no automatic acceptance is implied.

A measurement result contains more than the digits on an instrument. Identify what was measured, where, with which method and instrument, under what relevant conditions, and with what uncertainty. Resolution is the smallest displayed step; it is not the same as accuracy. Metrological traceability connects a result to a reference through a documented calibration chain whose steps contribute uncertainty. A calibration label by itself does not describe the entire measurement.

For an invented noncritical sliding fit, suppose the drawing permits a shaft from 9.90 to 9.95 millimetres and a hole from 10.00 to 10.10. The smallest possible clearance is the smallest hole minus the largest shaft: 10.00 minus 9.95 equals 0.05 millimetre. The largest is 10.10 minus 9.90 equals 0.20. This calculation describes the stated limits. It does not choose tolerances for a real mechanism.

Now consider a shaft reading of 9.94 millimetres with a stated expanded uncertainty of 0.03 millimetre. The interval from 9.91 to 9.97 extends beyond the upper drawing limit. An unconditional 'pass' would conceal that fact. Apply an agreed decision rule appropriate to the task, or obtain a better measurement and review the result. The example does not prescribe a universal acceptance rule.

Check the physical meaning of the dimension. Measuring at one location cannot establish the whole form of a bent, tapered or outofround part. Burrs, temperature differences, force of contact and the chosen datum may matter. Record the observations needed for the particular feature instead of treating one convenient reading as a complete inspection.

The resulting inspection note should allow another person to understand both the number and the decision. Keep the instrument identity, reference information, method, relevant uncertainty and acceptance basis with the job. This is especially valuable when a replacement is made locally and later installed by someone else. The record carries the meaning that the bare part cannot show.

Edison’s workshop depended on ordinary suppliers

United States workshops: supply, repair and records

Units and terms in this account

mm millimetre, 0.001 metre · ± plus or minus; stated tolerance or uncertainty · = equals