Stopping distance grows with speed squared
Constant deceleration model; reaction distance is a separate term
10 m/s at 5 m/s²: braking distance 10 m
20 m/s at 5 m/s²: braking distance 40 m
Distance = speed² ÷ (2 × deceleration)
At 10 m/s, a 1 second reaction adds another 10 m.
An ideal numerical comparison, not a prediction of a particular vehicle, surface or driver.
For a body slowing with constant acceleration magnitude a from speed v to rest, the ideal stopping distance is v² divided by 2a. With v = 10 metres per second and a = 5 metres per second squared, the distance is 10 metres. If the speed doubles while the deceleration magnitude remains the same, the distance becomes 40 metres. This is a model calculation, not a forecast for a particular vehicle or road.
Reaction distance is separate from braking distance. A one-second delay at 10 metres per second adds 10 metres before braking begins. Tyres, surface condition, gradient, brake condition and load distribution can change the actual stopping behaviour. A photograph of a car does not supply those parameters. Reaction travel and deceleration travel are separate terms in the total distance.
WORK: OpenStax, Rice University: work
UNITED STATES Cooling coffee: temperature difference drives heat transfer
Cooling is a time series, not one temperature
Illustrative model: T = 20 + 50 × exp(-0.05 × time in minutes)
Read the illustration’s labels
Cooling towards a constant room temperature
20
30
40
50
60
70
0
10
Temperature (°C)
Elapsed time (minutes)
Room: 20°C
T(t) = 20 + 50 exp(-0.05 t)
10 min: 50.3°C
Synthetic curve, not measured data
At 10 minutes: 50.3 °C
Record room temperature, cup, volume, probe position and time.
The curve contains calculated model values; it is not a set of measured experimental observations.
A cooling cup exchanges energy with its surroundings through conduction, convection and radiation; evaporation can also carry energy away from the liquid surface. Temperature and heat are different quantities. Temperature describes the thermal state, while heat is energy transferred because of a temperature difference. A temperature curve does not by itself tell how much energy left the cup unless mass and thermal properties are also known.
For a constant room temperature, Newton’s cooling model is T(t) = Troom + (Tstart - Troom) exp(-k t), with k positive. Here t is in minutes and k is 0.05 per minute. A start at 70°C in a 20°C room therefore gives about 50.3°C at ten minutes. The difference from the room temperature decays; the temperature itself does not decay towards zero. The sign convention matters. [QR-COOL]
A cooling record includes initial and ambient temperatures, water quantity, vessel geometry, lid state, probe position and elapsed time. Unequal starting temperatures or containers prevent a controlled comparison. Changes in room temperature alter the driving difference during the record; a single decay coefficient may then be inappropriate.
A temperature record uses elapsed time as its horizontal coordinate. A constant thermometer offset shifts every measured point. Stirring, drafts, evaporation and container thickness can change the cooling rate. A discrepancy between observations and the model calls for a review of these assumptions.
HEAT: OpenStax, Rice University: mechanisms of heat transfer
HEAT · source
Units and terms in this account
m/s metres per second, speed · m/s² metres per second squared, acceleration · m metre, a length unit · = equals · × multiplied by · ÷ divided by
= equals · × multiplied by · °C degree Celsius, a temperature unit · min minute, 60 seconds
°C degree Celsius, a temperature unit · = equals