Illustrative model: T = 20 + 50 × exp(-0.05 × time in minutes)
Read the illustration’s labels
Cooling towards a constant room temperature
20
30
40
50
60
70
0
10
Temperature (°C)
Elapsed time (minutes)
Room: 20°C
T(t) = 20 + 50 exp(-0.05 t)
10 min: 50.3°C
Synthetic curve, not measured data
At 10 minutes: 50.3 °C
Record room temperature, cup, volume, probe position and time.
The curve contains calculated model values; it is not a set of measured experimental observations.
A cooling cup exchanges energy with its surroundings through conduction, convection and radiation; evaporation can also carry energy away from the liquid surface. Temperature and heat are different quantities. Temperature describes the thermal state, while heat is energy transferred because of a temperature difference. A temperature curve does not by itself tell how much energy left the cup unless mass and thermal properties are also known.
For a constant room temperature, Newton’s cooling model is T(t) = Troom + (Tstart - Troom) exp(-k t), with k positive. Here t is in minutes and k is 0.05 per minute. A start at 70°C in a 20°C room therefore gives about 50.3°C at ten minutes. The difference from the room temperature decays; the temperature itself does not decay towards zero. The sign convention matters. [QR-COOL]
A cooling record includes initial and ambient temperatures, water quantity, vessel geometry, lid state, probe position and elapsed time. Unequal starting temperatures or containers prevent a controlled comparison. Changes in room temperature alter the driving difference during the record; a single decay coefficient may then be inappropriate.
A temperature record uses elapsed time as its horizontal coordinate. A constant thermometer offset shifts every measured point. Stirring, drafts, evaporation and container thickness can change the cooling rate. A discrepancy between observations and the model calls for a review of these assumptions.
HEAT: OpenStax, Rice University: mechanisms of heat transfer
HEAT · source
Shell-and-tube heat exchange: two fluid paths and one thermal boundary
A shell-and-tube exchanger transfers heat across a separating wall. Its fluid paths, temperature relationships and equipment limits must be considered together.
Two fluid passages and the tube wall
Read the illustration’s labels
Shell and tube: two separate flow paths
One tube pass; alternating segmental baffles guide the shell-side flow.
Tube-side
inlet
outlet
Shell-side inlet
Shell-side outlet
Tube sheet:
seals the two sides
Baffles support the tubes
and redirect the outside flow
Tube wall:
barrier between fluids
Heat crosses the wall.
Its direction depends on
the temperatures.
Fluid inside the tubes
Fluid outside the tubes
Conceptual cutaway.
No scale or operating
conditions are prescribed.
An original cutaway shows a bundle of tubes inside an outer shell. One coloured route passes through the tubes; the second travels through the shell around them, redirected by baffles. Separate arrows show heat crossing the tube walls. The tube sheets separate the passages. This is a conceptual view with no manufacturing scale or operating temperatures. [RD-H-DIAGRAMS]
Keep the two passages distinct
A shell-and-tube exchanger contains tubes within an outer shell. One fluid passes through the tube passages and another through the space around them. Heat crosses the separating material while the intended fluid circuits remain separate.
The supplied note places hot oil inside the tubes and cold water outside. That is an example arrangement, not a rule for every exchanger. Tube count, materials and the choice of which fluid occupies each side depend on the design. The text's 280 °C and 20 °C figures are unverified example inlet conditions, not settings for an identified machine. [RD-H-HX-DOE]
Flow arrangement changes temperature relationships
Baffles can support tubes and direct shell-side flow across a tube bundle. Multiple tube passes and shell-side paths complicate the simple picture of two streams moving in opposite directions. A shell-and-tube unit is not automatically a pure counterflow exchanger.
The useful temperature difference depends on conditions at both ends. Two inlet temperatures alone do not establish the outlet temperatures or the heat duty. The achievable transfer also depends on flow rates, fluid properties, area and the thermal resistance of the complete assembly. [RD-H-HX-ASHRAE, RD-H-HEAT-DOE]
Read the equation with its assumptions
For an appropriate steady heat-exchanger model, the mean-temperature-difference relation can be written q = U A F ΔTlm. q is heat-transfer rate in watts; U is the overall heat-transfer coefficient; A is heat-transfer area; ΔTlm is the logarithmic mean temperature difference; F accounts for the applicable flow arrangement relative to the reference arrangement.
For the ideal reference counterflow case, F is one. More complicated arrangements may require a correction. The relation belongs alongside energy balances for the streams, and its assumptions must fit the equipment. It is not the only equation needed to specify a working exchanger. [RD-H-HX-ASHRAE, RD-H-HEAT-DOE]
Separation is a design condition, not a guarantee
The intended boundary prevents the fluids from mixing, but a damaged tube, seal or joint can defeat that separation. Describing the equipment as guaranteeing zero mixing hides this failure mode. Pressure differences, material compatibility, fouling and maintenance influence performance and consequences.
The direction of fluid motion is different from the direction of heat transfer across the wall. A useful section distinguishes the tube-side inlet and outlet, shell-side inlet and outlet, tube wall and baffles. Pressure rating, permitted temperature and fluid compatibility come from the actual equipment specification; they cannot be read from a conceptual cutaway. [RD-H-HX-DOE, RD-H-HX-ASHRAE]
Words, symbols and component names
| Term | Meaning in this chapter |
|---|---|
| shell side / lado de carcasa | The fluid passage outside the tubes but inside the shell. |
| tube side / lado de tubos | The fluid passage through the tubes. |
| baffle / deflector | A component that can support tubes and guide shell-side flow. |
| q | Heat-transfer rate, measured in watts. |
| U | Overall heat-transfer coefficient, here expressed in W/(m²·K), with an area basis consistent with A. |
| A | Heat-transfer area in square metres, consistent with the coefficient U. Here A is an area symbol, not the ampere unit. |
| ΔTlm | Logarithmic mean temperature difference. It uses the relevant terminal temperature differences, not just the two inlet temperatures. |
| F | Dimensionless correction factor for the applicable flow arrangement relative to the reference case; one for ideal reference counterflow. |
| W | Watt, a unit of power equal to one joule per second. It is distinct from watt-hours of energy. |
| K | Kelvin, the temperature unit used here for temperature differences. A difference of one kelvin has the same size as a difference of one degree Celsius. |
| °C | Degrees Celsius. The supplied 280°C and 20°C are unverified example inlet temperatures, not operating settings. |
| m² | Square metre, a unit of area. |
| = | Equality within the stated mathematical model or definition; it does not remove the model's assumptions. |
| U A F ΔTlm | Adjacent factors are multiplied: coefficient × area × correction factor × mean temperature difference. |
Units and terms in this account
= equals · × multiplied by · °C degree Celsius, a temperature unit · min minute, 60 seconds
°C degree Celsius, a temperature unit · = equals
°C degree Celsius, a temperature unit
= equals · °C degree Celsius, a temperature unit · m² square metre, an area unit · × multiplied by
°C degree Celsius, a temperature unit · m² square metre, an area unit · = equals · × multiplied by