Inside a galilean telescope
Museo Galileo inventory 2427 · quantitative reconstruction with ideal thin lenses
The museum dates this surviving instrument to about 1610. It catalogues a biconvex objective with focal length 1,330 mm and a plano-concave eyepiece with focal length -94 mm; the tube is 1,273 mm long. Those are object records. The ray construction below is a modern simplification. [D365]
Read the illustration’s labels
A
B
C
D
E
F
G
H
| Key | Small-print annotation |
|---|---|
| A | Positive objective |
| B | Negative eyepiece |
| C | Converging inside tube |
| D | Parallel incident rays |
| E | Parallel out |
| F | Objective focus without eyepiece |
| G | Ideal lens separation: 1,330 - 94 = 1,236 mm |
| H | 94 mm |
Magnification is an angle ratio
M = -f_o/f_e = 1,330/94 ≈ 14.1 (o: objective; e: eyepiece). The ideal pair is afocal: parallel rays enter and leave parallel. Lens separation is between model lens planes, not the tube ends. Vertical dimensions are exaggerated; this axial bundle does not show the field of view.
An object can change after its maker
Inventory 2428 offers a useful warning: its original eyepiece was lost and the museum records a nineteenth-century replacement. Do not describe every surviving component as original. Keep manufacture, repair and present configuration as separate statements. [D366]
A lit summit beyond the shadow boundary
Modern teaching model · invented dimensions, not measurements from the engraving
A ray can illuminate a high point while lower ground behind the tangent point remains in shadow. Galileo used the separation of bright summits from the illuminated portion in his argument. Here a sphere and a tangent ray isolate the geometry; they omit actual terrain and viewing projection. [D364]
Derive before inserting numbers
Read the illustration’s labels
Enlarged radial height h
Q: surface · P: peak
d
T
P
R
R + h
Parallel light
Illuminated side
Shadow side
OT is perpendicular to TP.
OTP is a right triangle.
Main drawing: R:d = 5:1.
Inset enlarges the height.
(R + h)² = R² + d²
h = sqrt(R² + d²) - R
R is the sphere’s radius. d is the tangent distance from T to the lit peak P, not an arc along the surface. h is the radial height above Q. All lengths must use the same unit.
Exactly stated teaching values
Choose R = 1,000 mm and d = 200 mm. Then h = sqrt(1,040,000) - 1,000 = 19.8039 mm, or 19.8 mm rounded. The approximation d²/(2R) gives 20.0 mm. Its difference here is 0.1961 mm. These are calculations for the chosen model, not historical lunar measurements.
In the drawing: Enlarged radial height h; Q: surface · P: peak; d T P; R R + h; Parallel light; Illuminated side Shadow side; OT is perpendicular to TP.; OTP is a right triangle.; Main drawing: R:d = 5:1. Inset enlarges the height.
Do not read d from a decorative image: projection, orientation, scale and uncertainty must first be established.
The 2005 Charon occultation: three observing tracks
Event: 11 July 2005. ESO chart released 4 January 2006.
The related illustration appears earlier in this volume · page 1948
An occultation occurs when a nearer body blocks a background source. Timings from different sites constrain a projected outline. ESO is the European Southern Observatory; JPL is the Jet Propulsion Laboratory.
Creative Commons Attribution 4.0 International, https://creativecommons.org/licenses/by/4.0/. Unmodified source image.
Historical fitted chords from El Leoncito in Argentina, Paranal and San Pedro de Atacama in Chile. The labelled historical radius belongs to that analysis; use the separate dated JPL table for the present atlas value.
Units and terms in this account
mm millimetre, 0.001 metre · = equals · ≈ approximately equal to
= equals · mm millimetre, 0.001 metre
ESO European Southern Observatory, an intergovernmental astronomy organisation with observing facilities in Chile · JPL Jet Propulsion Laboratory, managed by the California Institute of Technology for NASA