Reverse the frame to find its zero
Two fixed foot positions / an error that changes sign
Read the illustration’s labels
Reversal finds the working zero
Keep the same two foot positions; exchange the feet between readings
First orientation
412 mm
Feet exchanged
428 mm
Example zero: (412 + 428) / 2 = 420 mm along the same crossbar scale.
Working zero = midpoint
(412 + 428) / 2 = 420 mm. Repeat both orientations on the same pads. Use the spread of repeated readings as evidence of repeatability.
Zero is found by reversal. A nominal 1,200 mm foot spacing needs a 12 mm check shim for a 1% grade.
Vitruvius describes the chorobates in Book VIII of his architectural treatise: a long levelling rule with supports, plumb references and a water channel when wind interferes with the hanging lines. The record is evidence that ancient builders compared distinct ways of establishing level. Our compact workshop frame is a modern teaching instrument inspired by the same physical references. It is not presented as an archaeologically exact reconstruction.
An A-frame carries a plumb line from its apex to a mark on a crossbar. The line responds to gravity, but the crossbar's geometric midpoint is not automatically the level mark. The legs may differ in length, the pivot may be off-centre and the timber may be irregular. Reversal lets the instrument find its own working zero on two fixed foot positions.
Set the feet on points P and Q and mark where the string crosses the bar. Exchange the feet without changing the ground points and mark the second crossing. For a rigid frame with repeatable foot contact and symmetrical reversal, the midpoint of the two readings is the operational level mark. If the crossings are 412 and 428 mm along the bar, mark 420 mm as zero. The midpoint cancels the first-order fixed offset while the ground slope changes sign.
Check that cancellation rather than assuming it. Return to the first orientation and repeat several times, allowing the bob to settle. A spread of several millimetres means the field zero should not be recorded to tenths. Wind, a swinging bob, flexing joints or a foot settling into soil can defeat the model. Use small hard bearing pads, keep them in position and record the string-reading range. A heavier bob can settle differently but does not cure a bending frame.
For a chosen 1.200 m foot spacing, a 1 percent grade corresponds to 12 mm height difference. Place a measured 12 mm shim under one foot on a verified level support, observe the reading and mark the grade position separately from the zero. Repeat with the shim under the opposite foot. This empirical calibration uses the actual frame geometry. It avoids pretending that one millimetre on an arbitrary crossbar always represents a universal ground slope.
The frame and the water hose can check each other because their vulnerabilities differ. One depends on rigid geometry and a free plumb line; the other on connected fluid, equal pressure and a stable meniscus. Agreement after reversing and transferring a known height is more persuasive than repeated readings from one untested instrument. The hidden craft is the design of a test that makes an error change sign while the desired quantity stays recoverable.
Plane table and alidade
Read the illustration’s labels
Plane table: board, battens and support
600 mm board length
Underside of 600 × 450 mm board
Approx. 9 mm plywood
Two battens: 400 × 20 × 15 mm
Clamp to an existing stable table.
Fasteners must not break the top.
Support design is not a tripod plan.
The board is 600 × 450 mm in this editorial example. Two 400 × 20 × 15 mm battens stiffen the underside. Select the actual fastening length from the measured board and batten thicknesses. Two suitable clamps connect the assembly to an existing stable table.
Units and terms in this account
mm millimetre, 0.001 metre · = equals · % percent, parts per hundred
mm millimetre, 0.001 metre · m metre, a length unit · × multiplied by