Median exp(μ) 97.514 nm
Population mean exp(μ + σ²/2) 109.212 nm
Mode exp(μ − σ²) 77.744 nm
This checks the poster arithmetic. It does not recover the original specimen data or validate the fitted distribution.
The particle poster retained in the ZeusC gallery prints lognormal parameters μ = 4.580 and σ = 0.476. Here μ, pronounced mu, denotes the mean of the natural logarithm of the modelled diameter divided by a reference unit; σ, sigma, is its standard deviation. Taking the logarithm of a dimensional quantity without stating the reference unit obscures the meaning. For this audit the reference diameter is 1 nm, one nanometre.
For a lognormal population with these parameters, the median is exp(μ), the arithmetic population mean is exp(μ + σ²/2), and the mode is exp(μ - σ²), each multiplied by the reference unit. Substituting the printed numbers gives about 97.514 nm, 109.212 nm and 77.744 nm respectively. Rounded to one decimal place, those are 97.5 nm, 109.2 nm and 77.7 nm. The latter two differ from the poster's displayed 110.8 nm and 79.5 nm.
This is an arithmetic audit of the parameters printed on the poster. It does not establish the properties of the specimen photographed there. The original raw diameters, calibration and fitting procedure have not
μ and σ describe logarithms relative to the stated unit. Population formulas and finite-sample summaries are distinct.
been supplied. The reported mean of a finite sample also need not equal the population mean calculated from rounded fitted parameters. Preserve both the original label and the corrected calculation so readers can see exactly what was checked.
The geometric mean of positive sample values is exp(mean of their natural logarithms). It is not generally identical to the sample median. In a lognormal population model, the geometric mean and median coincide, but a finite observed sample will not necessarily reproduce that equality. Likewise, exp(mean of logs) and mean of untransformed values are different operations. A spreadsheet formula that substitutes one for the other can change the interpretation without changing the apparent units.
Finally inspect the model rather than admiring its curve. A skewed distribution may combine two populations, censor large objects at the image edge or reflect a thresholding artefact. Plot the individual measurements, identify the selection policy and compare alternative explanations. More counted objects reduce some sampling variation but do not repair biased field selection. The value of the audit is that every substitution can be repeated with a hand calculator and the raw record.
The related illustration appears earlier in this volume · page 2091
Open the complete related drawing · page 2097
| Key | Small-print annotation |
|---|---|
| A | UNITED STATES |
A four-wire measurement asks where the voltage was sensed
Where are current and voltage connected?
Read the illustration’s labels
Four-terminal teaching arrangement
2 × AA
Vref
Vtest
A
B
C
D
E
F
| Key | Small-print annotation |
|---|---|
| A | Separate sense leads define the voltage boundary; the source remains a two-cell battery. |
| B | 1 kΩ limiter |
| C | 100 Ω reference |
| D | 100 Ω test |
| E | about 3 V |
| F | Solid: current path. Dashed: voltage sensing. One meter may be moved only if conditions stay stable. |
Units and terms in this account
NASA National Aeronautics and Space Administration · nm nanometre, one billionth of a metre · = equals
nm nanometre, one billionth of a metre · = equals
AA A standardized cylindrical battery size designation, not an acronym · × multiplied by · kΩ kilohm, 1,000 ohms · Ω ohm, electrical resistance · V volt, electrical potential difference · mA milliampere, 0.001 ampere