Current 3.0 V / (1000 + 100 + 100) Ω 2.5 mA

Reference drop 0.0025 A × 100 Ω 0.250 V

Test resistance Vtest / (Vref / Rref) 100 Ω

Meter stays in voltage mode. Its sense contacts are placed inside the current connections.

A two-wire resistance reading includes the path through the leads and contacts used to drive the measuring current. This is often harmless for a large resistor but can dominate a small resistance. If the component is 1.00 Ω and the two leads contribute 0.20 Ω each, a simple model predicts 1.40 Ω. More digits on the display do not remove those 0.40 Ω. The missing information is the location of the voltage measurement.

In a four-terminal, or Kelvin, arrangement, one pair of wires carries current while a separate pair senses voltage near the chosen boundaries of the object. A high-input-resistance voltmeter draws relatively little current through its sensing leads, so their voltage drops are reduced. The arrangement does not remove every error: contact placement, current distribution, thermal effects and the definition of the test length still matter. Put the sense contacts inside the current contacts and mark their positions.

The large classroom board in this reader avoids an ammeter connection. A known 100 Ω reference resistor sits in series with a 1 kΩ current-limiting resistor and the test resistor, powered by two AA cells. Measure the voltage across the reference and then across the test resistor with the same voltmeter. Calculate current as Vref/Rref and test resistance as Vtest divided by that current. Use stable conditions between readings, or use two meters simultaneously if their suitability is known.

A four-terminal connection reduces lead effects; it does not eliminate every contact, temperature or geometry error.

With ideal 3.0 V cells, a 1 kΩ limiter, a 100 Ω reference and a 100 Ω test resistor, the current is 2.5 mA. Both 100 Ω resistors then have a 0.250 V drop. These are calculated expectations, not promised readings from purchased parts. Measure the supply voltage, note component tolerances and keep the meter in voltage mode. The board's terminal spacing makes current and sense connections visible to a group.

Small thermoelectric offsets can matter in more demanding work. A numerical reversal example illustrates the principle without pretending the teaching board is a precision laboratory. At +0.020 A, suppose the sensed voltage is +0.0201 V; at -0.020 A it is -0.0199 V. Half the difference removes a constant 0.0001 V offset, giving R = (Vplus - Vminus)/(2I) = 1.00 Ω. The cancellation assumes unchanged offset and symmetric current.

Label each measurement by its contact pair, polarity, elapsed time and instrument setting. Take a zero-current reading when investigating offsets. Compare two-wire and separate-sense arrangements while keeping the test geometry fixed. The practical skill is to identify which voltage belongs to the intended quantity. This same discipline is useful when a salvaged connector, cable joint or switch appears to be the source of an unexplained loss.

Magnification and resolution are different limits

Enlarging an image cannot recover detail that the optical system did not resolve. The drawing separates the collection angle from the overlap of image responses.

Read the illustration’s labels

Magnification enlarges an image; resolution separates detail

LIGHT COLLECTION

Objective lens

θ

Specimen point

NA = n sin θ

n: refractive index of the medium

θ: half-angle collected by the lens

SCHEMATIC IMAGE RESPONSES

Two separated peaks

Overlapping peaks

Curves illustrate overlap, not measured

point-spread functions or a test result.

Wavelength, aperture, illumination and the chosen criterion all matter.

CriterionRelationshipIllustrative value
Abbe lateral estimateλ / (2 NA)423 nm
Rayleigh point separation0.61 λ / NA516 nm

Both figures use wavelength λ = 550 nm and numerical aperture NA = 0.65. They describe different resolution criteria under idealised optical assumptions, not a measured capability of the phone stand. NA = n sin θ, where n is the refractive index and θ is the collected half-angle. A nanometre (nm) is one billionth of a metre.

Source: Nikon MicroscopyU, Resolution and The Diffraction Barrier in Optical Microscopy. https://www.microscopyu.com/microscopy-basics/resolution

Units and terms in this account

AA A standardized cylindrical battery size designation, not an acronym · × multiplied by · kΩ kilohm, 1,000 ohms · Ω ohm, electrical resistance · V volt, electrical potential difference · mA milliampere, 0.001 ampere

Ω ohm, electrical resistance · AA A standardized cylindrical battery size designation, not an acronym · kΩ kilohm, 1,000 ohms · V volt, electrical potential difference · mA milliampere, 0.001 ampere · A ampere, electric current · = equals

NA Numerical aperture; n × sin θ in the optical collection geometry · = equals · n refractive index of the optical medium · sin sine, the trigonometric function of an angle · θ theta, the light-collection half-angle · nm nanometre, one billionth of a metre · λ lambda, the wavelength of light