Read the illustration’s labels
Phone copy stand: joints and camera position
Concept dimensions from the existing account; this stand has not been load-tested
Base dimension 450 mm
Arm projection 250 mm
Tether to upright
Lens over the sheet
Plan
Arm section: 40 × 30 mm
Upright section: 40 × 40 mm
Base thickness: 18 mm
Upright height is not specified.
The 300 g phone allowance is a design assumption, not a tested load rating.
1. Cut the base, upright and arm to the listed sizes. Smooth edges and inspect for splits. Mark a centreline on the 450 mm base dimension. The rear upright sits inside the base edge; the arm projects toward the centre, not outside the footprint.
2. Fit two angle brackets between the upright and base with eight 4 × 16 mm screws. Drill pilot holes appropriate to the timber and check actual bracket thickness and screw penetration so no point emerges through the base.
3. Attach the arm near the top of the upright with the other two brackets and eight screws. Keep its 40 mm dimension vertical for greater bending stiffness. Check that the phone lens will lie above the centre of the reference sheet.
4. Drill a mounting clearance hole near the arm end for the 1/4-20 bolt. Fit the clamp using washers and the verified bolt length. Check socket depth before tightening; use spacing washers or a correctly shorter bolt so the bolt does not bottom out inside the clamp.
5. Place four non-slip pads beneath the base. Fit the phone with the clamp’s retaining lips engaged and a separate tether to the upright. Keep the phone at or below 300 g and stop if the clamp, arm or base moves. This teaching stand has not been physically load-tested for this edition.
6. Position the reference and specimen in the same plane. Adjust the clamp angle until grid squares remain approximately square across the view. Use diffuse room light or an existing lamp positioned clear of the stand; do not add a hot lamp to the wooden arm.
7. Use a timer or remote shutter to avoid touching the phone during exposure. Repeat after removing and replacing the specimen. Save an untouched image and record camera, distance, lens choice, lighting and scale.
8. If the setup does not frame the intended sheet at this fixed height, use a smaller field within the calibrated plane or redesign the stand with a verified stable geometry. Do not raise it on loose blocks or extend the arm beyond the base.
Revision and handover
In the drawing: The first scanning electron microscope in La Plata’s museum service
Article published 2015
The related illustration appears earlier in this volume · page 2083
Robert Hooke, Micrographia (1665). Digitised copy: Wellcome Collection, b30326370.
Original instrument engraving. This is historical evidence of an observation arrangement, not a dimensioned fabrication drawing.
Historical collection image
Units and terms in this account
mm millimetre, 0.001 metre · g gram, 0.001 kilogram · × multiplied by
g gram, 0.001 kilogram
