Reading uncertainty: distinguish distance, angle and time
Read the illustration’s labels
2 mm lateral uncertainty
shown exaggerated
CALCULATION
NEAR-NOON RESULT
arctan(2 / 300)
0.382°
4 × angle / sin(34.6°)
about 2.69 minutes
In the drawing: 2 mm lateral uncertainty shown exaggerated; CALCULATION NEAR-NOON RESULT; arctan(2 / 300) 0.382°; 4 × angle / sin(34.6°) about 2.69 minutes
Origin
Reading radius: 300 mm
Read the illustration’s labels
ONE CONTRIBUTION ONLY
This does not include level, alignment, style geometry or clock-reference uncertainty.
A
| Key | Small-print annotation |
|---|---|
| A | Original teaching drawing · Edition 59 · Read the figure caption for source and example status |
Local sensitivity calculation near noon for the 34.6°‐south model. A 2 mm lateral reading interval at 300 mm radius corresponds to about 2.7 minutes; it is not a complete uncertainty budget.
A calculated line angle is exact within its model, while a constructed and read dial has finite uncertainty. Separate the contributions instead of assigning one impressivelooking accuracy number. The latitude may be rounded, the base may tilt, the style may lean, the shadow may be broad and the observer may interpolate differently. The reference clock and the equationoftime calculation also have limits.
Near noon, differentiating the hourline relation gives a useful sensitivity: a small change in the line angle equals sin(latitude magnitude) times the change in solar hour angle. At 34.6 degrees, one degree of lineangle error corresponds locally to about 7.04 minutes of solar time. The factor is not the same at every hour, so this noon estimate must not be applied blindly to the entire face.
Consider a reading position 300 millimetres from the origin. A twomillimetre lateral uncertainty there subtends about arctan(2/300), or 0.382 degree. Applying the nearnoon sensitivity gives approximately 2.69 minutes. This is an illustrative contribution from one reading interval. It is not proof that the completed instrument is accurate to 2.69 minutes.
Write the dominant limits in ordinary words. For example: the shadow boundary could be placed within roughly two millimetres; the direction reference disagreed with an independent check by a stated amount; the board was level within the instrument’s demonstrated resolution. If a quantity was not measured, identify it as unresolved. Combining guessed tolerances with a formula does not create a tested uncertainty budget.
Use uncertainty to improve the design. A longer readable ray can make a small angular change easier to see, provided the shadow remains distinct and the board stable. Strong contrast can improve the edge reading. A rigid, inspected support can reduce movement. Increasing the number of printed minute ticks without improving these conditions adds decoration but may not add information. Choose labels that the actual geometry and observing method can support.
A field record that another observer can repeat
Uncertainty, repairs and a complete observation record
Record raw observations separately from calculations
| Record | Information to preserve |
|---|---|
| Session | Site, date, observer, instrument and purpose. |
| Time reference | Clock source, civil UTC offset and time convention. |
| Raw observation | Reading, shadow position, conditions and units. |
| Calculation | Coordinates, equation-of-time convention and derived result. |
| Configuration | Geometry, level checks, photographs and repair dates. |
Give the observation session a clear heading: site identifier, date, observer, instrument configuration and purpose. State the coordinate pair and source, clock reference, actual civil offset and equation-of-time convention. These distinguish the observation from a local-time or camera-timestamp assumption.
Keep raw observations in one part of the record and derived values in another. The raw part contains the clock reading, shadow mark, measured coordinates or indicated hour, and conditions. The derived part contains the corrected solar time, predicted position and residual. This separation allows a later correction to an offset or transcription without pretending that the observer saw something different.
Attach configuration evidence: a side-view photograph of the style, a plan showing true directions, the measured pin height if a shadow board is used and the date of the last level check. Keep instrument repairs on a separate page. If the base is lifted between observations, the resulting data should not share a configuration identifier with the earlier fixed setup.
For a digital copy, preserve the original record as well as the cleaned table. Define file names and units, retain a second copy and document corrections. CSV means comma-separated values, a plain-text table format; SVG means Scalable Vector Graphics, an editable drawing format. Neither format guarantees truthful data. That depends on the relationship between saved entries, observations and the documented method.
Sundial records and maintenance history
A useful final handover contains the design, the exact source images, the calculation record, the raw observations, the corrections and the limits of the result. A reader can follow the chain from original intent to present behaviour. This is the practical connection between a sundial and the larger rebuilding project: a tool becomes dependable when its construction, operation and care are intelligible to someone other than its maker.
Jacques Lucas: latitude travels with the instrument
European instruments: portability and different dial forms
Units and terms in this account
mm millimetre, 0.001 metre · ° degree, an angle unit · × multiplied by
° degree, an angle unit · mm millimetre, 0.001 metre
UTC Coordinated Universal Time, the international civil time standard; Argentina used UTC minus three hours for this event
= equals