Read the illustration’s labels
0.0
0.2
0.4
0.6
0.8
1.0
In the drawing: 0.0 0.2 0.4 0.6 0.8 1.0
A ruler gives distance. It does not directly give molecular mass. A calibration connects distance to standards under stated conditions. In a common working range for denaturing protein gels, the logarithm of apparent mass is approximately related to relative migration. Relative migration, written Rf here, is the band distance divided by the reference dye-front distance measured from the same origin.
Distance becomes mass through a calibration
Synthetic reference ladder: a doubling distance is not a doubling mass
Relative migration Rf
Mass in kDa; logarithmic spacing
40 mm band / 80 mm front = 0.5
Between 80 and 40 kDa: geometric mean = 56.6 kDa
39-41 mm reading gives about 59.1-54.2 kDa in this model only.
The points and their relationship were constructed for teaching. No experimental gel is represented.
Use the synthetic teaching board: the dye front is 80 millimetres from the origin. Standards of 160, 80, 40, 20 and 10 kilodaltons are placed at 16, 32, 48, 64 and 80 millimetres. These are deliberately constructed values, not results from a real gel. Every extra 16 millimetres halves the assigned mass. A mass axis with equal steps of 10 would therefore misrepresent the relationship.
For an unknown band at 40 millimetres, Rf is 0.5. Interpolating halfway between the 80 and 40 kilodalton standards in logarithmic space gives the square root of 80 times 40, approximately 56.6 kilodaltons. An arithmetic average would give 60, a different answer. The interactive calculator shows the regression and warns when a band lies outside the calibrated interval.
Measurement uncertainty belongs beside the answer. In this constructed model, shifting the band centre from 39 to 41 millimetres changes the estimate from approximately 59.1 to 54.2 kilodaltons. That interval
reflects only the chosen one-millimetre reading variation. It does not include uncertainties in the standards, gel behaviour, staining or fitted model. Do not present it as a complete confidence interval.
Follow the sources
Bio-Rad: protein standards and molecular-mass estimation
Rf: Relative migration: band distance divided by reference‐front distance, both from the same origin.
James Clerk Maxwell Born 13 June 1831 · Died 5 November 1879
Intensity, background and the temptation of a dark band
Count signal after accounting for background
A transparent arithmetic example, not a protein assay
Read the illustration’s labels
REGION A
REGION B
CLIPPED
In the drawing: REGION A; REGION B; CLIPPED
200 pixels
Raw 18000 units; background 20 per pixel; net 14000.
Raw 14000 units; background 20 per pixel; net 10000.
At the recording limit: larger signals may look equal. Do not infer equal quantities.
Net A / net B = 14,000 / 10,000 = 1.4
Bright-band signal convention. A dark-on-light image requires an explicitly recorded transformation.
A darker band may indicate more stained material, but darkness is not automatically proportional to protein quantity. The image can saturate. Background can vary. Different proteins can bind a stain differently. The question must be narrowed before numbers become meaningful: what is being compared, by what detection method and within what usable range?
If a dark-on-light image is used, first define how darkness is converted to positive signal. Keep the transformation with the record. Do not switch conventions between samples. An equal number of pixels is not an equal physical area when two pictures have different magnifications. Saturated pixels cannot reveal how far above the recorded limit the true signal lay.
Units and terms in this account
kDa Kilodalton, a molecular-mass unit · mm millimetre, 0.001 metre · = equals
= equals