Resolution, repeatability and suitability are different

Read the illustration’s labels

60 g

tare

59.5 g

1 g DISPLAY STEPS

0.1 g DISPLAY STEPS

More displayed

digits do not by

themselves prove

accuracy.

HYPOTHETICAL DIFFERENCE

RELATIVE TO

PROPORTION

1.0 g

about 1.68%

453.6 g

about 0.22%

These are sensitivity examples, not allowed weighing tolerances. Choose suitable

equipment and a defined method.

Original teaching drawing · Read the figure caption for source and example status

The drawing distinguishes resolution, repeated readings and suitability. The numerical error illustration is hypothetical and not an allowed tolerance.

Suppose a scale changes only in onegram steps. Displaying a calculated target as 59.5340 grams does not make that scale capable of resolving the target. Equally, a scale displaying 0.1 gram can still be affected by calibration, load position, air movement, temperature and operating practice. Resolution is the smallest displayed increment; uncertainty describes the limits attached to a measurement result under stated conditions.

A proportional comparison shows why small ingredient masses deserve attention. A hypothetical onegram difference relative to 59.5 grams is about 1.68 percent. Relative to 453.6 grams, the same difference is about 0.22 percent. These numbers illustrate sensitivity; they are not acceptable deviations for a soap formulation. The actual weighing requirements must come from the approved method and suitable equipment.

Before a batch, use the scale manufacturer's instructions and the workshop's measurement procedure to establish that the device is fit for purpose. A check mass is a reference with its own identity and evidence. An arbitrary coin, a packet marked with a nominal retail weight or a remembered household item is not automatically a calibrated reference. Record which check was made and what result would prevent use.

Repeated readings can reveal instability, but agreement between repetitions is not proof of correctness. A biased scale may repeat the same wrong value. In the diagram, three readings are close together in one example and widely scattered in another; neither illustration alone establishes the true mass. The purpose is to separate repeatability from the wider question of measurement quality.

A record should make its limits readable. State the scale identifier, capacity, resolution, relevant check and the precision actually recorded. Preserve the raw observation before rounding a reported result. If the equipment is unsuitable, obtain suitable equipment rather than rounding a critical ingredient until it seems convenient. This principle applies to soap, repair parts and food weighing alike: a calculation can only use the information that the measurement actually supports.

Saponification values carry their own units

Read the formula arithmetic before using it

Units and terms in this account

g gram, 0.001 kilogram · % percent, parts per hundred

KOH Potassium hydroxide · NaOH Sodium hydroxide