A correction preserves the original entry and its reason

Read the illustration’s labels

ORIGINAL ENTRY

Water: 132.2 g

Corrected: 133.2 g

Reason: retained scale image

confirms transcription error.

DIFFERENT EVENT: A SPILL

Amount lost is unknown.

Preserve the observation; do

not invent a corrected mass.

STATUS: HOLD FOR REVIEW

EVERY CORRECTION

PRESERVE

What changed and why

Original entry and supporting evidence

Who / when / review

Consequence for batch interpretation

In the drawing: ORIGINAL ENTRY; Water: 132.2 g; Corrected: 133.2 g; Reason: retained scale image confirms transcription error.; DIFFERENT EVENT: A SPILL; Amount lost is unknown. Preserve the observation; do not invent a corrected mass.; STATUS: HOLD FOR REVIEW; EVERY CORRECTION PRESERVE; What changed and why Original entry and supporting evidence; Who / when / review Consequence for batch interpretation

Original teaching drawing · Read the figure caption for source and example status

A correction should improve the record while preserving what was originally written. On paper, the usual practical pattern is a single line through an incorrect entry, the corrected entry nearby and a dated explanation with the responsible person's identification. A digital system needs an equivalent change history. The exact procedure belongs to the workshop's document controls, but the principle is stable: a later reader must be able to distinguish the observation from the correction.

Consider an invented transcription error. An operator's retained scale image shows 133.2 grams, while the form says 132.2 grams. If the image is clearly identified and contemporaneous, the correction can cite that evidence. The corrected form should not pretend that the original entry never existed. If no independent evidence survives, the operator cannot turn a recollection into a certain measurement by writing it more neatly.

A spill is a different event. The planned amount may have been weighed correctly, yet less material reached the mixing vessel. Crossing out the target and writing a guessed actual amount does not solve the missing evidence. Describe when and where the spill occurred, what is known, what is uncertain and why the batch is held. Do not silently add extra material after the reaction has begun to force the paperwork back toward the plan.

Corrections to identity can be more serious than corrections to a decimal. A wrong ingredient lot, ambiguous container or mislabeled sample can break the link between a test and the batch it supposedly represents. A valid test result attached to the wrong sample is not valid evidence for this batch. The diagram therefore shows document links as well as numbers.

At review, ask whether the correction changes the batch's interpretation. A harmless spelling correction and an unresolved alkali mass do not deserve the same decision. Preserve both the person who made the entry and the person who reviewed the consequence. This is how a batch record supports learning: the next operator sees the real failure mechanism and the improvement made, rather than an immaculate sheet that conceals a repeated problem.

Follow the mass without inventing missing material

The batch record as a working document

Reconcile a defined mass boundary

Read the illustration’s labels

INPUT: 646.3 g

MOULDED

620.0 g

RESIDUE

18.0 g

SAMPLE

5.0 g

UNEXPLAINED

3.3 g

620.0 + 18.0 + 5.0 + 3.3 = 646.3 g

In the drawing: INPUT: 646.3 g; MOULDED; 620.0 g; RESIDUE; 18.0 g; SAMPLE; 5.0 g; UNEXPLAINED; 3.3 g; 620.0 + 18.0 + 5.0 + 3.3 = 646.3 g

Unexplained difference ≈ 0.51% of input. Do not rename it evaporation without evidence. All values are invented.

An invented 646.3‐gram input account is divided among moulded material, vessel residue, sample and unexplained difference. It is not a chemical acceptance test.

A mass account helps locate losses, but it must define its boundary. Are you comparing ingredients weighed, ingredients transferred, material poured into moulds or bars after curing? These totals refer to different moments. Water loss, retained residue, sampling and spills can change the result. A single yield percentage without those boundaries is difficult to interpret.

The example starts with a hypothetical recorded input of 646.3 grams, using the displayed rounded metric column. Suppose 620.0 grams reaches the moulds, 18.0 grams is measured as vessel residue and 5.0 grams is removed as a separately identified sample. The accounted output is 643.0 grams. The remaining difference is 3.3 grams, about 0.51 percent of the stated input. These invented values demonstrate reconciliation; they are not observed results from the source recipe.

Do not automatically call the remaining difference evaporation. It could include measurement uncertainty, unrecorded transfer loss, material on a utensil, a transcription error or an inadequately defined weighing boundary. The correct label is unexplained difference until evidence supports a more specific description. A plausible story should not be promoted into a measured fact.

Later curing changes the mass again. Compare like with like: the same identified sample, consistent packaging status and a recorded date or elapsed time. A reduction in bar mass is not a direct measurement of reaction completion or free alkali. The chemistry and testing chapters explain why those questions need different evidence. [CH1, CH4]

A good yield worksheet separates planned mass, actual input, moulded output, retained sample, documented residue and unresolved difference. Give each number its unit and basis. When material is recovered from a vessel, any proposal to reuse it belongs to a defined reviewed process; it should not vanish from one record and appear anonymously in another. This discipline is useful well beyond soapmaking. It makes missing information visible while it can still be investigated and keeps a tidy percentage from disguising an incomplete account.

pH, free alkali and the release question

What a test or electronic log can establish

Units and terms in this account

g gram, 0.001 kilogram

g gram, 0.001 kilogram · = equals

% percent, parts per hundred · ≈ approximately equal to · pH A logarithmic measure of hydrogen-ion activity