Plan sampling with the laboratory Ask the laboratory which containers, preservation, sampling points and delivery times its methods require. Include microbiological and chemical parameters appropriate to drinking, irrigation or the intended use. Arsenic is a documented concern in Argentina; regional maps do not clear an individual well. Do not infer potability from taste or a photograph.
Read the illustration’s labels
A
B
C
D
E
F
G
H
I
| Key | Small-print annotation |
|---|---|
| A | Test The Water, Not Its Appearance |
| B | Analytical drawing. Example quantities are labelled; geometry is not a site survey. |
| C | Well / monitored point |
| D | Measured discharge |
| E | Label sample point, date and operating state. |
| F | Soil and rock |
| G | Water-bearing formation |
| H | Concept section only. No well depth, screen size, safe setback or sustainable yield is assigned. |
| I | HISTORICAL CONTEXT |
Record the physical system Log well depth, casing, seal, screen interval, pump setting, static water level, test pumping rate, water-level response and recovery. Include sampling date and operating conditions. Have the test designer set the duration and observation intervals. There is no universal short test that proves a reliable estate supply.
Illustrative yield arithmetic A measured rate of 0.8 L/s equals 2,880 L/hour. Four pumping hours would produce 11,520 L if that rate can be maintained. This multiplication is a volume calculation, not permission to pump or a sustainable-yield estimate. Reject any comparison that equates pump nameplate flow with proven well delivery.
Acceptance and failure Set the demand and permitted treatment burden first. A supply fails the project if it cannot sustain the required use, cannot be made suitable at an acceptable cost, or lacks a lawful route to use. Test treated water as well as raw water. Document waste from treatment and the approved disposal route.
In the drawing: HISTORICAL CONTEXT; Test The Water, Not Its Appearance; Analytical drawing. Example quantities are labelled; geometry is not a site survey.; Soil and rock; Water-bearing formation; Well / monitored point; Measured discharge; Label sample point, date and operating state.; Concept section only. No well depth, screen size, safe setback or sustainable yield is assigned.
D442 · John Snow
Declare the users and uses Example: eight residents at an assumed 100 L/person/day for all household uses give 800 L/day. A 200 m² garden receiving a hypothetical net 3 mm/day needs 600 L/day. At an assumed 80% irrigation application efficiency, gross irrigation is 750 L/day. Total modelled use is 1,550 L/day before other loads.
Storage calculation Three days at 1,550 L/day require 4,650 L of usable water. A nominal 5,000 L tank may provide less usable volume after dead storage and operating limits. Separate potable and irrigation duties as required. Fire reserve, livestock, visitors and treatment losses have not been included; add them explicitly rather than hiding them in the household allowance.
Rainfall calculation A 200 m² roof receiving 25 mm of rain has a gross yield of 5,000 L. With an illustrative total collection factor of 0.8, the captured volume is 4,000 L. It arrives during the event, not evenly each day. Subtract actual losses and available tank capacity. Catchment water requires assessment and treatment appropriate to its use.
Use a monthly balance For each month record opening storage, lawful supply, rainfall captured, treatment losses, demand and closing storage. Simulate a dry period and a pump failure. Annual rainfall totals alone can hide a seasonal deficit. Garden demand here is a calculation example; replace it with crop, weather and soil measurements.
D450 · Aranjuez
A Measured Household Water Budget
Daily example
Household 800 L Irrigation 750 L
1,550 L/day × 3 = 4,650 L usable
Day 1: 1,550 L Day 2: 1,550 L Day 3: 1,550 L
Add fire reserve, livestock, visitors and treatment losses. Nominal tank volume is not usable volume.
Units and terms in this account
L litre, a volume unit
L litre, a volume unit · m² square metre, an area unit · mm millimetre, 0.001 metre · % percent, parts per hundred · = equals · × multiplied by