When a river probe needs a bottle

Field sampling with the DH-81 U.S. Geological Survey / 2010 Public domain, USGS

A probe and a sample bottle answer linked questions

Identify the sampling equipment in the USGS reference. A sensor reading needs time, location, calibration and maintenance history. A bottle needs identity and handling records through to laboratory analysis.

A fixed probe can capture a short-lived change that a monthly visit misses. A bottle collected at the same point can travel to a laboratory with a chain of identification. The US Geological Survey’s National Field Manual treats these as complementary records. Conductivity depends on temperature and the dissolved ions. Turbidity responds to light scattered by particles. A rise in one cannot identify the substance responsible for a rise in the other. Record depth, time, calibration and the condition of a sensor face. A fouled optical window can create a trend that looks convincingly environmental.

Read it with a pencil and a record

Prepare one blank station label, one sample label and one observation sheet. Copy the same station ID and time onto both. Preserve sensor units and laboratory method separately; a conductivity number cannot identify every dissolved substance.

Measuring the air above the rubbish

Horse-drawn ash cart, New York City Miscellaneous Items in High Demand, PPOC, Library of Congress / 1896 Public domain

One tall object can fool a fill reading

The 1896 ash-cart image records a collection service before electronic fill sensing. For a modern bin, depth minus the air gap gives an estimated filled depth. A sloping surface makes a single central reading unrepresentative.

A horse-drawn ash cart in an 1896 New York photograph documents the work a fill-level sensor is meant to help schedule. A downward-looking transducer measures the air space above a surface. If the usable depth is 0.80 m and the measured gap is 0.20 m, a level surface fills 75 percent of the depth. This is a geometric estimate. One tall object under the sensor can create a small measured gap in a bin that still has free space at its edges. Check several manual observations before using the estimate to dispatch a collection.

With a 200 mm-deep empty box and ruler, compare a level 50 mm layer with one tall object. Measure the gap at five positions. Keep each reading rather than presenting the smallest gap as the fraction of the whole box that is full.

Units and terms in this account

FAA Federal Aviation Administration · USGS United States Geological Survey · US United States

US United States · PPOC Prints and Photographs Online Catalog, Library of Congress

m metre, a length unit · mm millimetre, 0.001 metre