ZeusC supplied additions, sheet 010. Watermark preserved. Underlying authorship not confirmed.

The sheet compares an undeformed frame, a deflected shape and member-force diagrams. A drawn deflection may be exaggerated for clarity. The load diagrams need their own supports, dimensions and units; a structural perspective alone cannot establish whether that calculation represents the completed building.

Visible featureHow it relates to this plate
Undeformed frameThis is the reference geometry used to compare the other diagram states.
Deflected shapeDisplacement is shown separately from the original geometry and may be magnified for visibility.
Member-force diagramsThese describe calculated effects within members. Values depend on the assumed loads, restraints and scale.