A courtyard house as a record of flows

Argentina first / modern comparative study, not a reconstruction of Casa Padilla

Read the illustration’s labels

OPEN

COURT

WHAT THE NUMBERED POINTS REQUIRE

1

Entry: measure the actual clear

2

Gallery: keep circulation distinct

3

Court: light, drainage and air are

A

B

C

D

E

F

G

H

I

J

KeySmall-print annotation
AFront rooms
B14.4 m
C3 × 6 m
DDrain to a verified discharge point
Eroute.
FKitchen
GWet zoneWork area
Hfrom storage.
ISTREET / ENTRY
Jseparate checks.

Dimensioned architectural study. No member sizes, foundation design, glazing schedule or compliance approval are implied.

Argentina: a house shaped by the lot

8.4 m outside

Section: follow the water

4 Wet zone: trace supply, waste and isolation.

5 Rain inlet: keep a record of overflow and cleaning.

6 Rooms: record use, openings and changing moisture.

Casa Padilla in San Miguel de Tucumán is a useful place to begin because its heritage record describes a particular building. Dating from around 1860, it occupies an 11 by 70 metre lot. Its long arrangement follows two parallel axes, with successive rooms and a substantial entrance passage, the zaguán. The record also describes an ironandglass inner screen between the entrance and the interior. These are features of that house, not a universal Argentine floor plan.

The adjacent drawing is a modern comparative study. It uses an 8.4 by 14.4 metre outer outline and an open court within a sequence of rooms, passage and service spaces. It is deliberately not labelled as a reconstruction of Casa Padilla. The room divisions explain what to observe; they do not specify a foundation, beam size, ventilation rate or permission to build.

Rain reaches a building as many small impacts but leaves through a few concentrated outlets. In this illustration it runs down the roof, travels left along the gutter, descends the pipe and enters the covered tank. The overflow has its own route away from the building. Following that complete journey makes a roof plan easier to understand than looking at the roof covering alone.

Rain runs down a tiled roof, left along a gutter to its downpipe, into a covered tank and out through an overflow channel.

Rain lands on the roof, travels left along the gutter, drops through the downpipe and enters the tank at the right. Overflow continues away from the tank. The arrows identify the direction of water movement in this illustrative system; they do not specify the dimensions or drinking-water quality of a real installation.

Contemporary explanatory illustration created with Higgsfield for this account. Arrows show direction: down the roof, left to the downpipe, down and into the tank, then along the overflow channel. This scene is not a surveyed installation or a complete plumbing specification; it does not establish drinking-water quality. The quantities below remain the stated hypothetical example.

A measured water example

Suppose a roof catchment has a horizontal projected area of 48 square metres. For a 24 millimetre event and an assumed runoff factor of 0.80, the collected volume before further losses is 48 × 0.024 × 0.80 = 0.9216 cubic metres, about 922 litres. Rain depth multiplies horizontal catchment area, not the larger area of the sloping roof sheets.

Record a floor datum and measure along the drainage route. A 100 millimetre difference across 5 metres corresponds to a 2% slope: 0.10 / 5 = 0.02. This is an arithmetic example, not a prescribed slope for every pipe or surface. Direction, trapped low points, outlet capacity and the applicable design all matter.

A built-up roof: layers, edges and drainage

The supplied cutaway shows how a low-slope roof meets its perimeter and outlet. It explains component relationships, but does not supply a complete roof design.

Built-up roof corner and scupper

The cutaway relates deck, roofing layers, aggregate surfacing and perimeter drainage. It bears a HomeTips copyright credit. The printed 2x4 label and ambiguous Drip Cap arrow are received annotations, not a verified construction specification.

Reading the cutaway

The illustration opens a roof corner to expose timber support, a deck, layered roofing, aggregate surfacing and the edge outlet. These are different parts of one assembly. The deck carries loads; the roof covering controls water; edge metal and flashings maintain continuity where the horizontal surface ends or rises against another surface.

The raised perimeter and the outlet create changes of direction in the roof surface. Water control at these junctions depends on the continuity of the covering and flashing. Component names alone do not establish the products, lap details or fixings needed for a particular assembly. [RD-H-BUR-VA]

Bituminous layers and surfacing

Built-up roofing combines reinforcing layers with compatible bituminous materials. The supplied note uses tar and asphalt as if they were the same material. They are not: asphalt and coal-tar roofing products have distinct specifications and compatibility requirements. An existing assembly must be identified before a repair material is selected.

Aggregate surfacing can protect a suitable built-up covering from exposure and form part of the specified roof system. It should not be described automatically as loose ballast holding any membrane in place. The required layers, attachment, insulation and vapour control depend on the chosen assembly and the building conditions. [RD-H-BUR-VA]

Where rainwater leaves

A scupper is an outlet through a roof edge or parapet. In this drawing, water is intended to reach the outlet and then a downpipe. The roof still needs a suitable drainage fall and unobstructed paths. An outlet cannot correct every low spot, and the presence of a downpipe does not prove that its capacity is adequate.

Flashing directs water across junctions rather than behind them. A complete drainage design also considers what happens if the normal outlet is obstructed. The supplied illustration gives no verified primary or overflow capacity, outlet elevation, roof slope or drainage area. [RD-H-BUR-VA, RD-H-FLASH-PNNL]

What the labels cannot establish

The note marked 2x4 describes a nominal lumber size in this illustration. It is not an instruction to build every roof edge with that member. The arrow labelled Drip Cap is visually ambiguous because it points toward the timber region rather than clearly identifying the complete metal detail.

No fastening schedule, deck capacity, membrane product, expansion allowance or local climatic basis is given. The drawing therefore belongs beside a component explanation, with its uncertainty stated. It cannot stand alone as a detail for construction or as proof that ponding and leakage have been eliminated. [RD-H-BUR-VA, RD-H-FLASH-PNNL]

Words, symbols and component names

TermMeaning in this chapter
BURBuilt-up roofing: a layered bituminous roofing system.
asphalt / coal tarDistinct roofing-material categories that must not be treated as interchangeable repair products.
scupper / salida de parapetoAn opening through a roof edge or parapet that allows water to drain.
flashing / babetaA component that directs water across a roof junction and protects the transition between surfaces.
UVUltraviolet radiation, one form of solar exposure affecting roofing materials.
2x4 nominal lumberA nominal lumber designation in the supplied illustration, not a verified finished measurement or a prescribed roof-edge size.
Units and terms in this account

m metre, a length unit · × multiplied by

m metre, a length unit · = equals · × multiplied by · % percent, parts per hundred

UV Ultraviolet Electromagnetic radiation with wavelengths shorter than visible violet light