A practical handover At the weekly meeting the grower signs the planting window, the irrigation lead demonstrates water delivery and the storekeeper reports shortages. If the pump test slips, reserve the nursery space or move the day’s crew to a field already supplied. Record the change before dispatching people or plants.
Six stations, six different frost histories
Station Series Mean last Latest last Days/yr
Aeroparque 1956-2012 15 Jul 2 Sep 1
Ezeiza 1956-2012 8 Sep 15 Nov 16
Pergamino 1950-2011 13 Sep 23 Oct 22
Corrientes 1962-2012 15 Jul 26 Aug 1
La Consulta 1970-2011 1 Oct 14 Nov 65
Bariloche 1956-2012 19 Dec 31 Dec 117
FAUBA, historic station series at 0 °C. Days/yr is mean annual frost-day frequency. Last-frost dates use the years in the source table for that statistic.
1956-2012
Same period at Aeroparque and Ezeiza, different exposure and frost frequency.
The same metropolitan area can require different plans Aeroparque and Ezeiza cover the same historical period. Their mean annual counts are one and sixteen frost days. A city nursery planning a delivery to the conurbano needs the receiving plot’s conditions. Pergamino, farther inland, supplies another distinct record.
Read each column on its own terms These stations use minimum air temperature at or below 0 °C in a standard screen. The separate 3 °C agricultural indicator is a proxy for conditions near vegetation. The atlas calculates statistics from available observations and lists frost-free years separately. A historical extreme describes one series. It cannot promise a safe planting day.
From station to decision At La Consulta, use the spring record when reserving protection and staff for a vulnerable crop stage. At Bariloche, keep a protected production option available for longer. For Corrientes, plan around local rain and access as well as occasional cold. Check the current forecast and the actual bed before dispatch.
How much water reaches a 100 m² bed?
Agree the net refill A chosen 100 m² bed needs the equivalent of 10 mm of water at the root zone. The grower credits 4 mm of effective rain after inspecting wetting depth. Rainfall in a gauge can exceed the amount stored where roots can reach it. On sloping or crusted soil, inspect more than one position.
Convert depth to water and time One millimetre spread over one square metre equals one litre. A 6 mm deficit over 100 m² is 600 L net. At an assumed application efficiency of 75%, the system must deliver 600 ÷ 0.75 = 800 L gross. At a measured zone flow of 400 L/h, schedule two hours, subject to infiltration and available water.
Units and terms in this account
FAUBA Facultad de Agronomía de la Universidad de Buenos Aires · °C degree Celsius, a temperature unit
m² square metre, an area unit · mm millimetre, 0.001 metre · L litre, a volume unit · % percent, parts per hundred · = equals · ÷ divided by