A measurement, not a comfortable-looking room The 2011 NIST photograph shows a temporary fan and panel installed to test an enclosure. NIST Technical Note 1847 reports 573 m³/h at a 50 Pa pressure difference for the December construction stage, equivalent to 0.45 air changes per hour at that test pressure.

Keep the test conditions with the result That figure is not normal ventilation. Windows were installed while door openings and penetrations were sealed for the test. Record the enclosure stage, test pressure and opening configuration when comparing results. Earlier source record: 1204

The related illustration appears earlier in this volume · page 90

Read the illustration’s labels

ROOM, ENCLOSURE, JOINT: THREE SCALES

Cold-weather section; arrows show different heat-transfer paths

Designed vent

Keep functioning

Room sensor

Conduction

Air leak

Sunlight

Gold: insulation. Green: air-control layer and intended ventilation.

Air sealing cannot replace insulation or a ventilation plan.

In the drawing: ROOM, ENCLOSURE, JOINT: THREE SCALES; Cold-weather section; arrows show different heat-transfer paths; Conduction; Designed vent Keep functioning; Sunlight; Air leak; Room sensor; Gold: insulation. Green: air-control layer and intended ventilation. Air sealing cannot replace insulation or a ventilation plan.

Heat and cold: measure before you specify

Choose and measure the occupied space Keep exits, required vents and heating equipment operable. Record temperature, time, sensor position and outdoor conditions; avoid direct sun or a nearby heater. Use dry layers in cold conditions and shade in heat. Relocate when the room cannot meet occupants’ needs.

Inspect the joint before buying material Correct loose hinges and poor latch fit first. Measure both jambs and the head. Match the profile to the gap; clean and dry the surface. Dry-fit, join corners and attach as the product specifies. Open, latch and reopen the door without obstructing escape.

Count a specific example, not every doorway For the opening opposite, 4.90 m of seal plus a 10% cutting allowance means buying at least 5.39 m. The 0.90 m sweep is separate. Use one tape measure, marker, suitable cutter and cleaning cloth, plus the product-specified fixings and driver. Measure the actual opening before purchase.

Protect the whole system Sealing must not block designed ventilation, combustion air or drainage. A blower-door test changes pressure; a trained operator must manage combustion and other hazards. Test airflow is not occupied-room fresh-air supply. Insulation and air sealing address different heat-loss paths.

Units and terms in this account

NIST National Institute of Standards and Technology · m³ cubic metre, a volume unit · Pa pascal, pressure

m metre, a length unit · % percent, parts per hundred · = equals · × multiplied by · RSI Metric thermal resistance, measured in square metres kelvin per watt · m² square metre, an area unit · W watt, power · h hour, 60 minutes · kWh kilowatt-hour, energy