The related illustration appears earlier in this volume · page 90
Read the illustration’s labels
ROOM, ENCLOSURE, JOINT: THREE SCALES
Cold-weather section; arrows show different heat-transfer paths
Designed vent
Keep functioning
Room sensor
Conduction
Air leak
Sunlight
Gold: insulation. Green: air-control layer and intended ventilation.
Air sealing cannot replace insulation or a ventilation plan.
In the drawing: ROOM, ENCLOSURE, JOINT: THREE SCALES; Cold-weather section; arrows show different heat-transfer paths; Conduction; Designed vent Keep functioning; Sunlight; Air leak; Room sensor; Gold: insulation. Green: air-control layer and intended ventilation. Air sealing cannot replace insulation or a ventilation plan.
Heat and cold: measure before you specify
Choose and measure the occupied space Keep exits, required vents and heating equipment operable. Record temperature, time, sensor position and outdoor conditions; avoid direct sun or a nearby heater. Use dry layers in cold conditions and shade in heat. Relocate when the room cannot meet occupants’ needs.
Inspect the joint before buying material Correct loose hinges and poor latch fit first. Measure both jambs and the head. Match the profile to the gap; clean and dry the surface. Dry-fit, join corners and attach as the product specifies. Open, latch and reopen the door without obstructing escape.
Count a specific example, not every doorway For the opening opposite, 4.90 m of seal plus a 10% cutting allowance means buying at least 5.39 m. The 0.90 m sweep is separate. Use one tape measure, marker, suitable cutter and cleaning cloth, plus the product-specified fixings and driver. Measure the actual opening before purchase.
Protect the whole system Sealing must not block designed ventilation, combustion air or drainage. A blower-door test changes pressure; a trained operator must manage combustion and other hazards. Test airflow is not occupied-room fresh-air supply. Insulation and air sealing address different heat-loss paths.
Use combustion equipment only as designed Never use grills, camping stoves or generators indoors, or a gas oven for room heating. An open window does not make these uses safe. Maintain appropriate alarms and approved heaters; keep exhaust routes clear. Follow local emergency instructions if a carbon-monoxide alarm sounds. The heat example holds conditions constant and omits air exchange, other surfaces, bridges, solar gain and system efficiency.
Cut to the frame, then test the closure
Assumed opening: W = 0.90 m; H = 2.00 m
Two jamb seals: 2 × 2.00 m = 4.00 m
One head seal: 0.90 m
Total perimeter seal: 4.90 m net
Separate bottom sweep: 0.90 m net
Profile, fixings and joint allowance follow the product.
Unscaled detail. Dry-fit; latch, open and escape without obstruction.
A CONDUCTION EXAMPLE, NOT A HEATER SIZE Q = A × ΔT / RSI | A = 12 m²; ΔT = 20 K
RSI is the complete assembly resistance in m²·K/W.
RSI is thermal resistance expressed in the International System of Units, in square metre kelvins per watt (m²·K/W). Natural Resources Canada labels it “R-Value Système International”.
Rsi 0.5 480 w
Rsi 2.0 120 w
Difference: 360 W. Over 8 h at steady conditions: 2.88 kWh.
kWh : Kilowatt-hour A unit of energy. One kilowatt supplied for one hour equals one kilowatt-hour, or 1,000 watt-hours. m : Metre The base unit of length in the International System of Units.
Q / A : Heat-transfer rate / area In this equation Q is the heat passing each second, in watts, and A is the area of the assembly in square metres.
Natural Resources Canada: thermal resistance and RSI units
Units and terms in this account
NIST National Institute of Standards and Technology · m³ cubic metre, a volume unit · Pa pascal, pressure
m metre, a length unit · % percent, parts per hundred · = equals · × multiplied by · RSI Metric thermal resistance, measured in square metres kelvin per watt · m² square metre, an area unit · W watt, power · h hour, 60 minutes · kWh kilowatt-hour, energy
kWh kilowatt-hour, energy · RSI Metric thermal resistance, measured in square metres kelvin per watt · NIST National Institute of Standards and Technology